Field Station NPL-632 Instruction Manual
157
Specifications
7
Dual-axis tilt sensor
Angle measurement
Precision
Method
Liquid-electric detection
Compensation range
±3'
Reading system
Photoelectric incremental encoder
Diametrical detection for H/V circles
Circle diameter (reading)
88 mm (3.46 in.) (79 mm (3.11 in.))
Minimum display increment
360°
1'' / 5" / 10''
400G
0.2 mgon / 1 mgon / 2 mgon
MIL6400
0.0005 MIL / 0.02 MIL / 0.05 MIL
DIN18723 accuracy
2"/0.5 mgon
Precise mode
Prism
± (3 + 2 ppm x D) mm
1
at -10 °C t40 °C
(+14 °F t104 °F)
± (3 + 3 ppm x D) mm
1
at -20 °C through -10 °C; +40 °C t50 °C
(-4 °F t14 °F; +104 °F through122 °F)
1
These precisions apply to measurements of 5 m(16 ft) or more to a reflector sheet and 10 m(33 ft) or more
to a mini or standard prism. For measurements at shorter distances than these, the precision is ± 5 mm.
Reflectorless
± (5 + 2 ppm x D) mm at -10 °C t40 °C
(+14 °F t104 °F)
± (5 + 3 ppm x D) mm at -20 °C through -10 °C; +40 °C t50 °C
(-4 °F t14 °F; +104 °F through 122 °F)
Normal mode
Prism
± (10 + 5 ppm x D) mm
Reflectorless
± (10 + 5 ppm x D) mm
Содержание NPL-632
Страница 1: ...Version A1 1 0 May 2006 Field Station NPL 632 Instruction Manual ...
Страница 8: ...Contents viii Field Station NPL 632 Instruction Manual ...
Страница 14: ...Safety 16 Field Station NPL 632 Instruction Manual ...
Страница 110: ...4 Applications 96 Field Station NPL 632 Instruction Manual ...
Страница 168: ...6 Checking and Adjustment 154 Field Station NPL 632 Instruction Manual ...
Страница 177: ...C H A P T E R 8 Field Station NPL 632 Instruction Manual 163 System Diagrams 8 In this chapter Q System Components ...
Страница 180: ...8 System Diagrams 166 Field Station NPL 632 Instruction Manual ...
Страница 196: ...9 Communications 182 Field Station NPL 632 Instruction Manual ...
Страница 206: ...10 Error Messages 192 Field Station NPL 632 Instruction Manual ...