5
Menu Key
128
Pulse Laser Station NPL-302 Series Instruction Manual
Specify the azimuth bearing. To do this, enter a value in the AZ or P2 field. P2 is a
second point on the line.
Enter the horizontal distance along the baseline
(Sta), the horizontal distance perpendicular to the
line (O/S), and the vertical distance (dVD).
To calculate the coordinates of the point (PM),
press
[ENT]
in the dVD field. You can change the Z
coordinate here.
A negative value in the Sta field means
the opposite direction along the defined
bearing line.
A negative value in the O/S field is for the
left-hand side of the bearing line.
Содержание NPL-302 Series
Страница 1: ...H163E 05 10 TF 9 Pulse Laser Station NPL 302 Series Instruction Manual NPL 332 NPL 352 NPL 362 ...
Страница 4: ......
Страница 5: ...Safety 1 In this chapter Q Introduction Q Laser Safety Q Warnings and Cautions ...
Страница 12: ...Safety xii Pulse Laser Station NPL 302 Series Instruction Manual ...
Страница 28: ...1 Introduction 8 Pulse Laser Station NPL 302 Series Instruction Manual ...
Страница 46: ...2 Preparation 26 Pulse Laser Station NPL 302 Series Instruction Manual ...
Страница 82: ...3 Getting Started 62 Pulse Laser Station NPL 302 Series Instruction Manual ...
Страница 188: ...5 Menu Key 168 Pulse Laser Station NPL 302 Series Instruction Manual ...
Страница 196: ...6 Checking and Adjustment 176 Pulse Laser Station NPL 302 Series Instruction Manual ...
Страница 208: ...8 System Diagrams 188 Pulse Laser Station NPL 302 Series Instruction Manual ...