6) Technical characteristics
Nice S.p.a., in order to improve its products, reserves the right to modify their technical characteristics at any time without prior notice. In any
case, the manufacturer guarantees their functionality and fitness for the intended purposes.
Note: All the technical characteristics refer to a room temperature of 20°C (±5°C)
Technical Features of the TCE detection unit
Type:
Detection unit utilised to produce electro-sensitive protection equipment (ESPE), complete with
8.2K
Ω
constant resistance sensor devices used for the automation of doors and gates.
Adopted technology
2 independent channels with window comparators and relay output
Supply voltage
15÷28Vac (±15%) 50/60Hz; with insulation transformer which conforms with EN 61558
12÷30Vdc (±15%)
Absorbed current with 24 Vac:
< 200mA rms
Absorbed current with 24 Vdc:
< 50mA
Phototest input voltage:
Same limits as “Input Voltage”
Range of the sensitive device input (Rs):
Typical 8.2K
Ω
± 25% for the activated state (On)
Limits of the activated state (On):
with Rs > 4,725
Ω
and Rs < 10,925
Ω
Limits of the deactivated state (Off):
with Rs <1,520
Ω
or Rs > 18,900
Ω
Sensitive device cable length:
Max. 30m
Out1 Response Time:
<5ms (typical 3.3ms)
Out2 Response Time:
1,6s ± 25%
OUT1 and OUT2 output relay contacts:
Max. 0.5A and max. 48Vac (resistive load: cos
ϕ
=1)
OUT1 and OUT2 output relay contacts duration:
Mechanical lifespan > 1,000,000 cycles; Electrical lifespan > 200,000 cycles (at 0.25A 24Vcc)
Operating temperature:
-20 ÷ 55 °C
Use in acid, saline or potentially explosive
atmosphere:
No
Protection class:
IP 20
Dimensions and weight:
60x59x422 with flaps 60x38x422 without flaps/approx. 55g
To maintain the guaranteed level of safety of the TCE, regular main-
tenance must be performed at max. 6 month intervals.
The maintenance operations must be performed in strict
compliance with the safety directions provided in this manual
and according to the applicable legislation and standards.
1. Check all TCE parts for wear with special attention to dirt, ero-
sion, rust, overheating.
2. Perform all tests and checks as envisaged in the section "Test-
ing".
!
5) Maintenance
This product is made up of different materials, some of which can be
recycled, such as plastic container, others must be disposed of as
waste, such as electronic board.
1. Disassemble TCE following in reverse order the procedures
described in chapter “Installation”.
2. As far as possible, separate all parts that can or must be recycled
or disposed of according to special procedures.
3. Sort the various materials and consign them to local licensed
firms for recovery and disposal.
Some electronic components may contain polluting sub-
stances; do not pollute the environment.
!
6) Disposal
TCE has two signalling LEDs which indicate the state of the relays.
Normally, they are “ON”. If they are off, this indicates a state of alarm,
meaning that the sensitive device has either triggered or malfunc-
tioned.
State
Signalling Description
Led1: on
OUT1: On
Output N°1 Activated
Led1: off
OUT1: Off
Output N°1 Deactivated
Led2: on
OUT1: On
Output N°2 Activated
Led2: off
OUT1: Off
Output N°2 Deactivated
4) Diagnostics and Signals
TACTO
IP10
12 / 24 Vac/dc
Out 0,5A 48Vac/dc
Led 1
3
4
1
2
NO
NC
Foto
5
NC
Alt
2
1
5
4
3
Led 2
8