Safety infra-red beams func on.
All modes except P.I.R.A.C. auto-close.
Basic opera ng
features
If the safety beam input has been switched on, the control card will constantly monitor to ensure a set of safety beams is installed.
NB!
A set of safety beams must be installed and the safety beam input must be confi gured .
Below is an example of how the gates will behave whenever the safety beam input is ac vated.
Ac on
Response
Momentary BT trigger.
Gate begins
opening.
No buzzer tones.
Safety beam input
triggered while gate is
opening.
Gate con nues
opening
No buzzer tones.
At full open posi on.
Safety beam input s ll
triggered.
Gate stops and
waits for next
trigger to close.
No buzzer tones.
Momentary BT trigger.
Trigger is
ignored and
gate remains
open.
No buzzer tones.
Safety beam input
cleared.
Gate remains
in the full open
posi on un l
the next trigger
to close.
No buzzer tone.
Momentary BT trigger.
Gate begins
closing.
No buzzer tone.
Safety beam input while
the gate is closing.
Gate stops and
reverses open.
No buzzer tone.
At the full open
posi on.
Gate stops and
waits for next
trigger to close.
No buzzer tone.
Momentary BT trigger.
Gate begins
closing.
No buzzer tone.