www.milleredge.com
800-220-3343
1/5
IMAGE 1. RBAND INSTALLATION WITH GATE EDGE
RBAND RECEIVER
MOUNTED INSIDE OPERATOR
WITH EXTERNAL ANTENNA
OPERATOR
ANTENNA
WIRING
RBAND TRANSMITTER
MOUNTED NEAR SENSING
EDGE
SENSING EDGE
IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED
READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION
The Miller Edge RBand Monitored Gate Edge Transmitter/Receiver system is intended to provide a wireless connection between a
monitored sensing edge and a motorized operator that controls the associated gate. The RBand Receiver is compatible with up to 3
RBand Transmitters on 2 channels; 6 total transmitters. RBand meets the 2016 UL 325 requirements for monitored devices and has
been certified as a UL 325 Recognized Component. It is designed for use with operators that comply with 2016 UL 325 using a Miller
Edge 10K Sensing Edge.
1. PARTS LIST
RB-G-K10 Contents:
•
RBand Gate Edge Transmitter/Receiver System:
•
RBand Edge Transmitter (RB-TX10)
•
RBand Gate Edge Receiver (RB-G-RX10)
•
Receiver
antenna
•
(2) 3.6V AA lithium batteries*
•
(4) #6 pan head transmitter mounting screws
RB-TX10 Contents:
•
RBand Gate Edge Transmitter (RB-TX10)
•
(2) 3.6V AA lithium batteries*
•
(4) #6 pan head transmitter mounting screws
*Replacement
3.6V AA lithium batteries
can be purchased
at your local electronics store or via Miller Edge.
Required:
•
1/8” flat blade screwdriver
•
1/4” flat blade screwdriver
•
Miller Edge 10K (T2/blue band) Sensing Edge
•
Coaxial cable for exterior mounted antenna
•
Coaxial bulkhead adapter, female/female
Recommended:
•
Multi-meter capable of reading 10K
1
•
Mounting screws as required for receiver
2. RECEIVER: INSTALLATION
1.
Remove the operator cover and turn off the power to the gate operator.
2.
Determine where to place the external mounted antenna so it is in line of sight with the Transmitter(s) for the entire range of
travel [IMAGE 1]. Prepare the antenna coax as necessary.
3.
Remove the Receiver cover and mount the base inside the operator, positioning it for optimum ease of wiring.
4.
Connect power to the terminals marked
12/24 AC/DC
(polarity sensitive) on the
removable 8-pin connector
[IMAGE 2].
INSTALLATION INSTRUCTIONS
Models: RB-G-K10, RB-TX10
RB-G-K10_Inst_201
9
0
301