40
Basic opera ng
features
Auxiliary relay modes.
Strike lock mode.
User manual reference -
Page 15
With Strike lock mode selected, the auxiliary relay will pulse momentarily, half a second before the gate opens.
Whenever a lock is installed with the system, a separate ba ery backed up power supply matching the lock load must be installed. Failure to do
this can damage the charger and ba ery of the control unit.
Below is an example of strike lock mode when standard BT mode is ac ve.
Ac on
Response
Momentary BT trigger.
Auxiliary relay
ac vates.
No buzzer tone.
Half a second a er
the auxiliary relay has
ac vated.
Gate begins
opening.
No buzzer tone.
A er the
preprogrammed relay
on me.
Auxiliary relay
deac vates and
gate con nues
opening.
No buzzer tone.
Gate reaches open
posi on.
Gate stops.
No buzzer tone.
Momentary BT trigger.
Gate begins
closing.
No buzzer tone.
At full closed posi on.
Gate stops.
No buzzer tone.