Se   ng up the gate run  me. (Mandatory)

run

From Ready status

rdy

Before con  nuing with the run  me setup ensure the limit actuator has 

been installed correctly as per page 16 in this manual. Begin with the 
gate midway in its travel.

NB. To speed up the gate while running during this procedure, press and hold 

either the < or > bu  ons. 

Ac  on

Response

Descrip  on

Display

Buzzer

Gate/s

To enter the program 
menu. Press and hold the 

 bu  on un  l buzzer 

beeps.

Display and buzzer 

confi rms.

pr9

Scroll < or > to select the 

run  me setup op  on.

Display scrolls 

through op  ons.

run

Ensure gate is engaged 
midway and then press 

 

bu  on.

Display prompts 

you to confi rm gate 
closing direc  on. 

cl

dir

Confi rm gate closing 
direc  on by pressing and 

releasing either the < or > 

bu  on.

Gate closes slowly.

Display confi rms.

Lft
r9t

When the closed posi  on 

is reached and the closed 
limit is triggered. LED on.

Gate stops and starts 
opening.

lrn

Press and release the 

 

bu  on to stop the gate 

at the required open 

posi  on.

Gate stops opening. 
Display asks you to 

fi ne adjust the open 
posi  on if required.

adj

Fine adjust the open 

posi  on using the < or > 
bu  ons, if necessary.

Gate moves with 

each bu  on press in 
either direc  on.

adj

When sa  sfi ed with the 
open posi  on, press and 

release the 

 bu  on to 

save that posi  on.

Gate closes slowly.
Display and buzzer 

confi rms.

lrn

When the closed posi  on 

is reached and the closed 
limit is triggered. LED on.

Gate stops. Display 
and buzzer warn the 

profi ling is about to 

begin.

pro

Once warning tone has 
stopped.

Gate begins running 
open at full speed.

Display confi rms.

pro

When the previously 
programmed open 

posi  on is reached.

Gate stops and 
begins closing again 
at full speed. Display 

confi rms.

pro

When the closed posi  on 

is reached and the closed 
limit is triggered. LED on.

Gate stops. Display 

and buzzer confi rms.

dne

Scroll le   or right to next 
program op  on.

OR

rdy

EXIT back to ready 
status

Содержание E.T. Systems Drive 300

Страница 1: ...ET DRIVE300 INSTALLER 2016 001 001 Installer Instruc ons Low tra c 300kg Slide Gate Operator www et co za...

Страница 2: ...uto close me Page 23 Receiver programming and setup Page 29 Switching the AC monitoring and or built in charger on or o Page 30 Adjus ng the length of the slow speed at the ends of travel Page 30 Swit...

Страница 3: ...echanical ends of travel stoppers 5 Ensure all xed moun ng points such as the wall above the door in a garage door system or the posts in a swing gate system are sound and strong enough to allow prope...

Страница 4: ...ware of what to check for with regards to wear and tear that may need to be a ended to from me to me by the service provider 8 Is aware that a fa gued ba ery may not be disposed of in the general refu...

Страница 5: ...or 3 Plug in terminal connectors 12 Manual release 4 Manual release monitoring reed switch 13 Manual release lock 5 Ba ery 14 Electric motor 6 Transformer housing 15 Electric motor brush ports 7 Moun...

Страница 6: ...ler bearing clad in nylon be used The guidance system should be installed at the top edge of the gate whenever possible In cases where this is not possible the guidance system should never be below th...

Страница 7: ...el Gate Mass Star ng resistance Rolling resistance Max Duty Cycle Drive 300 300kg 30kgf 24 kgf 25 Where to posi on the gate motor Liquid ingress The ET Drive series motor models all carry an ingress p...

Страница 8: ...bu on box and terminated there 1 Courtesy lights twin earth 1 0mm back to motor housing and isolator switch 7 Free exit loop 1 5mmsilicone insulated single core exible stranded cable back to loop dete...

Страница 9: ...andard kit is supplied with J bolts so that the baseplate can be cast in concrete While this method o ers a nice solid base it takes more than 48hrs to install as the concrete must cure properly befor...

Страница 10: ...t trigger subsequent to the gearbox being engaged a er a manual release the gate will close at half speed The system is looking for the closed posi on which is the origin point This is known as refere...

Страница 11: ...M8 machine bolts and custom moun ng plates The gearbox distance from the gate can be adjusted backwards and forwards by up to 30mm Remember to ensure that there is enough space allowed between the fas...

Страница 12: ...correct This will cause unwanted rolling resistance especially in colder condi ons Where the wheel shrinkage will cause the gate to sit heavier on the pinion or when the rack is no longer square to th...

Страница 13: ...re the 2 lengths of rack marry correctly use an o cut of rack clamped upside down across the join of the 2 lengths Con nue to fasten the TEK screws as before When nished installing su cient rack to al...

Страница 14: ...ay not pass in front of it and must be posi oned so that it cannot be tampered with for the outside of the property This circuit must be cer ed by way of a C O C cer cate of compliance by a registered...

Страница 15: ...mally closed output M Motor red output 12V Ancillaries 12VDC power output M Motor black output 0V 0V Common output 0V 0V Common output ST Status LED output LC Closed limit input BM Safety beam detec o...

Страница 16: ...sten the actuator down onto the rack using either the M4 x 20 self tapping screw supplied with the kit or with a nut in the case of steel rack 4 Adjust the actuator so that it is approximately halfway...

Страница 17: ...play or save value on display Exit menu levels without saving Navigatebackward in menus decrease values or indicatele hand closing gate in run me setup func on Navigate forward in menus increase value...

Страница 18: ...18 Control card programming and setup Programming menu quick reference guide...

Страница 19: ...osed limit is triggered LED on Gate stops and starts opening lrn Press and release the bu on to stop the gate at the required open posi on Gate stops opening Display asks you to ne adjust the open pos...

Страница 20: ...isplay returns to programming menu op ons list for Scroll le or right to next program op on OR EXIT back to Ready status rdy irb Safety infra red beams setup From Ready status rdy Use this op on to en...

Страница 21: ...con rms pr9 Scroll or to select the bt setup op on Display scrolls through op ons bt With bt on the display press and release Display shows current op on status 5td Scroll or to the required BT mode o...

Страница 22: ...er con rms pr9 Scroll or to select the pedestrian se ng op on Display scrolls through op ons ped With Ped on the display press and release Display shows current pedestrian opening distance in 100mm in...

Страница 23: ...isplay press and release Display shows current op on status lrn With Lrn on the display press and release Display prompts you to select a func on bt Scroll or to the required receiver func on channel...

Страница 24: ...ll four bu ons must be set to the same format for this to work in the same way as this example While s ll transmi ng with the remote bu on press and release A er the bu on has been released the user a...

Страница 25: ...ress and release Display shows rst erase op on adr With Adr on the display press and release First user address displays 001 Scroll or to the user address that you would like to erase Display scrolls...

Страница 26: ...on the display press and release Display changes to Adr and buzzer beeps once adr Scroll or to select the Erase ALL memory op on Display scrolls through op ons all With ALL on the display press and h...

Страница 27: ...ny transmi er on the same frequency as the receiver being ac ve in the area the signal strength guide will display how strong the incoming interfering signal is Weak signal i Not appicable Low signal...

Страница 28: ...ce lrn Not appicable Use the or bu ons to select inf Display changes with each bu on press inf Not appicable With inF on the display press and release Buzzer beeps once and the display scrolls through...

Страница 29: ...es with each bu on press p5u Not appicable With PSu on the display press and release Display changes to Ac and buzzer beeps Ac Not appicable Scroll or to the required se ng Charger chr Not appicable A...

Страница 30: ...Slo and buzzer beeps 5lo Not appicable Scroll le or right to next program op on OR rdy EXIT back to standby status pcl Switching posi ve close mode on or o From Ready status rdy The gate can be in an...

Страница 31: ...r to the required se ng Strike lock mode lc1 Not appicable Mag lock mode Lc2 Receiver relay mode rc Courtesy light mode lit Alarm mode ala With required selec on displayed press and release If Lc1 Lc2...

Страница 32: ...ows coL To clear this condi on ac vate the manual release and clear the obstruc on Re engage the manual release as per page 10 of this manual and con nue to use the system as per normal Safety overloa...

Страница 33: ...buzzer tones Safety beam input triggered while gate is opening Gate con nues opening No buzzer tones At full open posi on Safety beam input s ll triggered Gate stops and waits for next trigger to clo...

Страница 34: ...trigger In Standard mode you have access to the following advanced features Holiday lock out and Party mode Ac on Response Momentary BT trigger Gate begins opening No buzzer tones At full open posi o...

Страница 35: ...he following advanced features Holiday lock out and Party mode NB For any auto close feature to work a pair of safety infra red beams must be installed and func oning correctly Ac on Response Momentar...

Страница 36: ...to work a pair of safety infra red beams must be installed and func oning correctly Ac on Response Momentary BT trigger Gate begins opening No buzzer tones Momentary BT trigger while gate is opening T...

Страница 37: ...ode NB For any auto close feature to work a pair of safety infra red beams must be installed and func oning correctly Ac on Response Momentary BT trigger Gate begins opening No buzzer tones Safety bea...

Страница 38: ...ll open posi on and the pedestrian transac on is cancelled The system then reverts to the BT trigger mode con gured There are two ways of ac va ng the PED func ons on this control card Either via the...

Страница 39: ...s cancelled The system then reverts to the BT trigger mode con gured There are two ways of ac va ng the PED func ons on this control card Either via the hardwired PED input or the PED receiver channel...

Страница 40: ...s can damage the charger and ba ery of the control unit Below is an example of strike lock mode when standard BT mode is ac ve Ac on Response Momentary BT trigger Auxiliary relay ac vates No buzzer to...

Страница 41: ...be installed Failure to do this can damage the charger and ba ery of the control unit Below is an example of magne c lock mode when standard BT mode is ac ve Ac on Response Momentary BT trigger Auxili...

Страница 42: ...and released Latch mode The transmi er must be released and pressed again to toggle the relay each me Ac on Response Momentary relay trigger Auxiliary relay switches on No buzzer tones Momentary rela...

Страница 43: ...ndard BT mode is ac ve Ac on Response Momentary BT trigger Auxiliary relay ac vates No buzzer tone Gate begins opening Gate reaches open posi on Gate stops No buzzer tone Momentary BT trigger Gate beg...

Страница 44: ...o open in this situa on but rather to con nue driving to their nearest armed response standby point or to the nearest police sta on This way they can ask for an escort onto the property Beam tamper al...

Страница 45: ...Response Momentary BT trigger Gate begins opening No buzzer tones At full open posi on Gate stops No buzzer tones Momentary BT trigger Gate begins closing No buzzer tones Momentary BT trigger Gate st...

Страница 46: ...condominium mode Ac on Response Momentary trigger from any transmi er bu on programmed into holiday lock out func on Buzzer begins toning and status LED comes on BT bu on while buzzer is sounding to...

Страница 47: ...d into holiday lock out func on Buzzer begins toning and status LED comes on BT bu on while buzzer is sounding to con rm that you want to ac vate Auto close override party mode If no BT bu on is press...

Страница 48: ...nd beep every 15 seconds for 5 minutes a er last gate transac on AC mains o Restore AC as soon as possible 4 x 0 5s ashes fol lowed by a 2 second pause 1 x 1 second beep every 15 seconds for 5 minutes...

Страница 49: ...fety overload triggered by physical overload See page 32 and Selec ng a safety level on page 20 ref Referencing the gate closed posi on See Referencing the closed posi on on page 10 e l Failure to see...

Страница 50: ...anufacturer modi ca ons to the product or components thereof 2 Any modi ca on to the installa on methods described in the installa on instruc ons 3 Any applica on or use of the product other than the...

Отзывы: