39
User manual reference -
Page 14
“PED” Pedestrian trigger.
(With safety beams installed)
Basic opera ng
features
The PED trigger is a higher security op on and is used when access to or from the property is limited to exclude motor vehicles.
If the safety beams are triggered while the gate is closing in pedestrian mode, the gate will only return to the preprogrammed pedestrian open
posi on.
If the BT trigger is ac vated at any me during the pedestrian rou ne, the gate will open to the full open posi on and the pedestrian transac on
is cancelled. The system then reverts to the BT trigger mode confi gured.
There are two ways of ac va ng the “PED” func ons on this control card. Either via the hardwired PED input or the PED receiver channel.
Ac on
Response
Momentary PED trigger.
Buzzer beeps
pre-run
warning.
A er buzzer silences.
Gate begins
opening.
No buzzer tones.
At previously
programmed
pedestrian opening
distance.
Gate stops and
the pedestrian
auto-close
mer starts
coun ng down.
No buzzer tones.
Momentary PED trigger
or safety beam circuit
trigger.
Pedestrian
auto-close
mer resets.
No buzzer tones.
Pedestrian auto-close
mer mes out.
Buzzer beeps
pre-run
warning.
A er buzzer silences.
Gate begins
closing.
No buzzer tones.
At full closed posi on.
Gate stops.
No buzzer tones.