16
Installing the limit actuator.
This diagram depicts how to install the limit actuator.
1. Push the gate up against the closed stopper.
2.
Remove the rack screw (Holding the nylon teeth to the steel angle) closest to being
in line with the limit switch. Or in the case of steel rack, weld a M4 x 20 machine bolt
upside down on top of the spine of the rack in line with the limit switch.
3.
Fasten the actuator down onto the rack using either the M4 x 20 self-tapping screw
supplied with the kit or with a nut in the case of steel rack.
4.
Adjust the actuator so that it is approximately halfway across the limit switch.
5.
Move the gate open and then closed again. Ensure the limit LED comes on before the
gate impacts with the closed stopper. (Posi ve closed mode will always close the gate
the last 50mm if selected in programming)
Wiring and termina on of the control card - Auxiliary relay examples.
Strike Lock Example
Magne c Lock Example
Courtesy light Example
Alarm zone Example