EDH0162En1040 – 06/99
1.18
MM4005
Introduction
M
Appears when the mechanical origin switch is in “high” state. As a stage
moves from one end of travel to the other, you will see this indicator
appear and disappear. This means that the stage has moved from one
side of the switch to the other. The state of this indicator does not affect
the normal operation of the motion device. For a complete description
of the home search algorithm see Section 4, Motion Control Tutorial.
+
Indicates that the positive direction (usually right) limit switch has been
activated (tripped).
NOTE
If both - and + appear, the motion device is either disconnected or a hard-
ware failure exists. On power-up sequence, the controller checks every
axis for this case. If found, it assumes that no motion device is present.
The axis is marked with Unconnected on the display and all commands
for it will be ignored.
At the end of each axis information line an OK is displayed if no error has
been detected. If a problem is detected on one of the axes, the message
ERROR will appear.
1.3.7
Display Structure
This section describes the most common menus and display functions.
Only local mode menus will be addressed since they represent the vast
majority of the front panel operations.
As described in Section 1.3.3 and illustrated in Fig. 1.4, the local mode is
divided into two sections: MOTOR power
and MOTOR power
.
1.3.7.1
MOTOR
Menus
1.3.7.1 MOTOR OFF Menus
When motor power is turned off — the controller “power-on” default mode
— the display function keys are as shown:
This is the “top level MOTOR
” menu.
Each function is defined as follows:
Toggles the display for additional status information.
Activates the motion program management and generation environment.
This mode can be activated from both MOTOR
and MOTOR
top
level menus. When selected, the function keys change to:
The creation and modification of a program section is addressed extensive-
ly in the Programming In Local Mode section of the Local Mode chapter.
Is described in detail in Section 2.2, Controller Configuration. A brief intro-
ductory description is provided here.
The top level setup menu (after pressing
) offers the choice of two
different setup categories and looks similar to Fig. 1.10.
SETUP
SETUP
QUIT
MODIFY
CREAT.
ON
OFF
PROG.
STATUS
OFF
SETUP
PROG.
STATUS
OFF
ON
OFF
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание MM4005
Страница 360: ...Section 7 Servo Tuning Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 368: ...Section 8 Appendices Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 405: ...EDH0162En1040 06 99 8 36 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 406: ...Section 9 Index Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...