8 - TROUBLESHOOTING
8 - TROUBLESHOOTING
###_8_###
FAULT CODE RESOLUTION
Error code index
NOTE:
If you have a fault code associated with a red light flashing and an audible alarm, shut the unit down and call
your dealer for support. For a fault code associated with a yellow amber light, record the code number and use the
Aux Override button to move past this fault code. If the code appears again, contact your dealer for support.
JOYNu – Control handle error
JOYNu appears on the instrument panel. Make sure that the control handles and the auxiliary thumbwheel are in the
neutral position. If JOYNu continues to be displayed contact your dealer for support.
OPRPr – Operator presence error
OPRPr appears on the instrument panel. Make sure that you are sitting in the operator seat, the seat belt is fully
engaged, and the restraint bar (if equipped) is in the down position. If OPRPr continues to be displayed contact your
dealer for support.
CRKOn – Hydraulic enable error (EH machines only)
CRKOn appears on the instrument panel. CRKOn indicates the OPERATE button is being pressed while attempting
to start the machine. Follow the starting procedure as described in this manual. If CRKOn continues to be displayed
contact your dealer for support.
The following is a display of error codes and associated functions.
1000 to 1999 (vehicle errors)
Code
Function
Description
Code
Function
Description
1002
Engine Coolant
Temperature
High Temperature
1350
Hydraulics Enable
Switch Implausible
State
1004
Hydraulic Oil Filter
Restriction
Filter Restricted
1511
Right Brake Light
Actuation
Open Circuit
1009
Hydraulic Oil
Temperature
High Temperature
1512
Right Brake Light
Actuation
Short Circuit
1014
Cluster System
Voltage
Over Voltage
1513
Right Brake Light
Actuation
Short Circuit to
Ground
1015
Cluster System
Voltage
Under Voltage
1521
Left Brake Light Actuation Open Circuit
1025
Load Control
Short Circuit
1522
Left Brake Light Actuation Short Circuit to
Ground
1030
Load Control
Open Circuit
1523
Left Brake Light Actuation Short Circuit
1041
RPM Monitoring
Over Speed
1531
Backup Alarm Activation
Open Circuit
1045
Fuel Level
Monitoring
Open Circuit
1532
Backup Alarm Activation
Short Circuit to
Ground
1201
Hydraulic Oil Filter
Restriction
Open Circuit
1533
Backup Alarm Activation
Short Circuit
1202
RPM Monitoring
Over Speed
1901
Power Supply
Supply Voltage
High
1203
RPM Monitoring
Open / Short Circuit
1903
Power Supply
Low Voltage
1204
Start Sequence
Engine State Plausibility
Check
1904
Power Supply
Input Voltage Out
of Range
1205
Hydraulic Enable
Short Circuit to Power
1905
Power Supply
Supply Voltage Out
of Range
1206
UCM
Configuration Time out
1906
Power Supply
Supply Voltage Out
of Range
8-1
Содержание 200 Series
Страница 60: ...2 SAFETY INFORMATION 2 44 ...
Страница 130: ...3 CONTROLS AND INSTRUMENTS 3 70 ...
Страница 154: ...5 TRANSPORT OPERATIONS 5 14 ...
Страница 184: ...7 MAINTENANCE L213 and L215 machines with Electro Hydraulic EH controls 47946332B 6 7 20 ...
Страница 185: ...7 MAINTENANCE L218 L220 L223 L225 L230 C227 C232 and C238 machines with Electro Hydraulic EH controls 47946330A 7 7 21 ...
Страница 250: ...7 MAINTENANCE 7 86 ...