7 - MAINTENANCE
18. Install the cap
(1)
onto the quick-disconnect drain fit-
ting
(2)
.
NOTE:
Make sure the o-ring is installed on the drain fitting
(2)
, if it is damaged, then replace with new.
NOTE:
The cap
(1)
is only hand tight on the drain fitting
(2)
.
RAPH17SSL0169QA
7
19. Install the cover
(1)
underneath the machine and se-
cure with the hardware
(2)
.
RAPH17SSL0168QA
8
20. Remove the engine oil dipstick
(2)
to provide
crankcase ventilation.
NOTICE:
Slowly fill to avoid flooding the valve cover with
oil.
21. Use an oil spout that is smaller than the engine oil fill
neck
(1)
, allowing air to pass around the oil fill neck.
Slowly add the correct type and quantity of oil, see the
oil table below.
NOTE:
Keep the oil fill spout in the upper half of the oil fill
neck.
22. Install the engine oil fill cap.
23. Install the engine oil dipstick.
24. Start the engine and run at idle speed. Check the en-
gine oil filter and drain plug for leaks. After
2 min
, stop
the engine, wait for
2 – 3 min
and check the engine
oil level.
25. Install access cover and secure with bolts
26. Close rear access door and engine hood.
93106871
9
Engine crank case oil
Capacity - with filter change
L213, L215, L218, L220
7.0 l
(
7.5 US qt
)
L223, L225, L230, C227, C232, C238
9.5 l
(
10 US qt
)
Specifications
NEW HOLLAND AMBRA UNITEK MASTERGOLD SBL CJ-4
7-58
Содержание 200 Series
Страница 60: ...2 SAFETY INFORMATION 2 44 ...
Страница 130: ...3 CONTROLS AND INSTRUMENTS 3 70 ...
Страница 154: ...5 TRANSPORT OPERATIONS 5 14 ...
Страница 184: ...7 MAINTENANCE L213 and L215 machines with Electro Hydraulic EH controls 47946332B 6 7 20 ...
Страница 185: ...7 MAINTENANCE L218 L220 L223 L225 L230 C227 C232 and C238 machines with Electro Hydraulic EH controls 47946330A 7 7 21 ...
Страница 250: ...7 MAINTENANCE 7 86 ...
Страница 288: ...10 ACCESSORIES 10 2 ...