Managed Switch CLI Manual, Release 8.0
Switching Commands
3-62
v1.0, July 2009
show gmrp configuration
This command displays Generic Attributes Registration Protocol (GARP) information for one or
all interfaces.
Format
no set gmrp interfacemode
Mode
• Interface Config
• Global Config
Format
show gmrp configuration
{<unit/slot/port> | all}
Mode
• Privileged EXEC
• User EXEC
Term
Definition
Interface
The unit/slot/port of the interface that this row in the table describes.
Join Timer
The interval between the transmission of GARP PDUs registering (or re-registering)
membership for an attribute. Current attributes are a VLAN or multicast group. There is
an instance of this timer on a per-port, per-GARP participant basis. Permissible values
are 10 to 100 centiseconds (0.1 to 1.0 seconds). The factory default is 20 centiseconds
(0.2 seconds). The finest granularity of specification is 1 centisecond (0.01 seconds).
Leave Timer
The period of time to wait after receiving an unregister request for an attribute before
deleting the attribute. Current attributes are a VLAN or multicast group. This may be
considered a buffer time for another station to assert registration for the same attribute in
order to maintain uninterrupted service. There is an instance of this timer on a per-Port,
per-GARP participant basis. Permissible values are 20 to 600 centiseconds (0.2 to 6.0
seconds). The factory default is 60 centiseconds (0.6 seconds).
LeaveAll Timer
This Leave All Time controls how frequently LeaveAll PDUs are generated. A LeaveAll
PDU indicates that all registrations will shortly be deregistered. Participants will need to
rejoin in order to maintain registration. There is an instance of this timer on a per-Port,
per-GARP participant basis. The Leave All Period Timer is set to a random value in the
range of LeaveAllTime to 1.5*LeaveAllTime. Permissible values are 200 to 6000
centiseconds (2 to 60 seconds). The factory default is 1000 centiseconds (10 seconds).
Port GMRP
Mode
The GMRP administrative mode for the port. It may be enabled or disabled. If this
parameter is disabled, Join Time, Leave Time and Leave All Time have no effect.
Содержание FSM726v3 - ProSafe Fast Ethernet L2 Managed Switch
Страница 4: ...v1 0 July 2009 iv...