Managed Switch CLI Manual, Release 8.0
Log Messages
8-2
v1.0, July 2009
Table 8-1: BSP Log Messages
Component
Message
Cause
BSP
Event(0xaaaaaaaa)
Switch has restarted.
BSP
Starting code...
BSP initialization complete, starting 7000
series application.
Table 8-2: NIM Log Messages
Component
Message
Cause
NIM
NIM: L7_ATTACH out of order for
intIfNum(x) unit x slot x port x
Interface creation out of order
NIM
NIM: Failed to find interface at unit x slot x
port x for event(x)
There is no mapping between the USP and
Interface number
NIM
NIM: L7_DETACH out of order for
intIfNum(x) unit x slot x port x
Interface creation out of order
NIM
NIM: L7_DELETE out of order for
intIfNum(x) unit x slot x port x
Interface creation out of order
NIM
NIM: event(x),intf(x),component(x), in wrong
phase
An event was issued to NIM during the
wrong configuration phase (probably Phase
1, 2, or WMU)
NIM
NIM: Failed to notify users of interface
change
Event was not propagated to the system
NIM
NIM: failed to send message to NIM
message Queue.
NIM message queue full or non-existent
NIM
NIM: Failed to notify the components of
L7_CREATE event
Interface not created
NIM
NIM: Attempted event (x), on USP x.x.x
before phase 3
A component issued an interface event
during the wrong initialization phase
NIM
NIM: incorrect phase for operation
An API call was made during the wrong
initialization phase
NIM
NIM: Component(x) failed on event(x) for
intIfNum(x)
A component responded with a fail
indication for an interface event
NIM
NIM: Timeout event(x), intIfNum(x)
remainingMask = “xxxx”
A component did not respond before the
NIM timeout occurred