background image

500-10001-001

EdgeMarc 4300T 

Converged Network 

Appliance

Installation Guide

Содержание EdgeMarc 4300T

Страница 1: ...500 10001 001 EdgeMarc 4300T Converged Network Appliance Installation Guide ...

Страница 2: ...Declaration of Conformity indicating that Industry Canada technical specifications were met It does not imply that Industry Canada approved the equipment Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer shoul...

Страница 3: ... 7 Back Panel 8 2 Getting Started 9 Physical Installation 9 Required Tools and Materials 9 Desktop Installation 10 Wall Mount Installation 10 Rack Mount Installation 10 Connecting the Power and Cables 11 Administration 12 A Specifications 15 B Warranty Information 17 Hardware Warranty 17 C Certification 19 FCC PART 68 NOTICE 19 INDUSTRY CANADA IC NOTICE 20 ...

Страница 4: ...EdgeMarc 4300T Converged Network Appliance Installation Guide 2 ...

Страница 5: ...s in a browser window Names of web GUI menus and input areas are in italic type Note This format highlights information that is important or that has special interest Chapter or Appendix Description Chapter 1 Overview Summary of the functional features of the 4300T describes front panel LEDs and physical features of the back panel Chapter 2 Getting Started Instructions for installing the 4300T and...

Страница 6: ...rmation that must be followed to avoid the risk of bodily injury Contact and Support Information Edgewater Networks Inc 2730 San Tomas Expressway Suite 200 Santa Clara California 95051 www edgewaternetworks com Phone 408 351 7200 General info edgwaternetworks com Sales sales edgewaternetworks com Edgewater Networks Inc Technical Assistance Center Phone 408 351 7200 ext 2 Support edgewaternetworks ...

Страница 7: ...T1 support Fractional T1 support Layer 2 protocol support for HDLC Cisco HDLC cHDLC PPP Frame Relay On board RJ 48 connector for easy direct connection T1 E1 framer and transceiver B8ZS HDB3 zero suppression Response to Inband Loop codes Manual payload loop through the GUI External transmit clock input and receive clock output headers Timing internal or external loop times from the network Provide...

Страница 8: ... be deployed initially as a low cost WAN access router and then licensed through software for more advanced VoIP features and increased call performance It is the ideal platform for service providers offering DIA hosted VoIP and managed security services or enterprises migrating to converged voice and data networks Feature Summary VoIP SIP MGCP and H 323 application layer gateway that allows a sin...

Страница 9: ...ch is on power is supplied to the unit B Status Off Self tests have failed the unit has not booted Green Self tests completed successfully Flashing Configuration is being written to permanent storage or an upgrade is in progress C T1 E1 Off The T1 is in an alarm state and not synchronized Green T1 E1 is not in an alarm state and synchronized D WAN Link Act Flashing indicates activity On indicates ...

Страница 10: ... Network LAN ports which connect the IP phone or an Ethernet switch the unit may also be configured through any of these ports using the web interface D Ethernet WAN port Used as an alternative to the T1 E1 WAN port most typically when connecting the 4300T to an existing T1 E1 WAN router cable or xDSL modem E Management console port Used to establish a local console session with the 4300T using a ...

Страница 11: ...hillips screw driver 2 round or flat head Phillips or slotted screws 1 inch long 2 hollow wall anchors If the unit will be mounted in a shelf Rack mount Kit Part EA 4300TRACKMOUNTKIT 19 If the T1 E1 port will be used to connect to WAN T1 cable to connect the T1 E1 port to a T1 line Warning To reduce the risk of fire use only 26 AWG or larger wire e g 24 22 20 etc to connect the T1 port on the unit...

Страница 12: ...installing the screws in drywall use hollow wall anchors to ensure that the unit does not pull away from the wall because of prolonged strain from the cable and power connectors 2 Remove the 4300T and accessories from the shipping container 3 Mount the 4300T on the wall Rack Mount Installation Note The 4300T 19 Rack Mount Kit is used with Revision B 4300T systems only These systems have the assemb...

Страница 13: ...outlet Warning Always connect the AC power cord to an AC outlet suitable for the power supply that came with the unit in order to reduce the risk of damage to it Connect one end of the AC power cord to the power adapter and the other one to the AC outlet Connect the plug from the power adapter to the Power Connector on the 4300T A small amount of force may be necessary to properly position the plu...

Страница 14: ...t will not be available If connecting to a WAN router cable modem or DSL modem connect the Ethernet cable to the Ethernet WAN port on 4300T and the other end to the WAN device Administration The 4300T may be configured using a web browser such as Internet Explorer or Netscape Navigator The 4300T is shipped with the pre configured IP address 192 168 1 1 for the LAN port To connect to the 4300T foll...

Страница 15: ...e system The initial 4300T main configuration menu appears 5 Select Network to start configuring the 4300T For instructions see the VOS for EdgeMarc User Manual Note For secure network management change the default user name and password as described in the VOS for EdgeMarc User Manual ...

Страница 16: ...EdgeMarc 4300T Converged Network Appliance Installation Guide 14 ...

Страница 17: ...k for EdgeMarc Product Family Specifications under Products EdgeMarc WAN Ports 1 x T1 CSU DSU or 10 100 Ethernet LAN Ports 4 x 10 100 Ethernet switched Serial Ports 1 x RS 232 Dimensions Height 1 7 inches 4 3 cm Width 10 inches 25 4 cm Depth 7 inches 17 8 cm Weight 2 lb 0 91 kg Power 12V 3A Warranty 1 year ...

Страница 18: ...EdgeMarc 4300T Converged Network Appliance Installation Guide 16 ...

Страница 19: ...conforming Hardware from Edgewater and return the nonconforming Hardware to Edgewater s designated repair facility freight prepaid with a statement describing the nonconformity Edgewater s exclusive obligations with respect to nonconforming Hardware shall be at Edgewater s option to advance replace such Hardware if it is determined to be defective or to refund to End user the purchase price paid f...

Страница 20: ...EdgeMarc 4300T Converged Network Appliance Installation Guide 18 ...

Страница 21: ... company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary The telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of the equipment If this happens the telephone company will provide advance notice in order for you to make the necessa...

Страница 22: ...ible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or...

Страница 23: ...Edgewater Networks 2730 San Tomas Expressway Suite 200 Santa Clara CA 95051 Phone 408 351 7200 info edgewaternetworks com http www edgewaternetworks com ...

Отзывы: