Managed Switch CLI Manual, Release 8.0
Utility Commands
6-85
v1.0, July 2009
no sflow sampler
Use this command to reset the sFlow sampler instance to the default settings.
sflow poller
A data source configured to collect counter samples is called a poller. Use this command to enable
a new sFlow poller instance for this data source if <
rcvr_idx
> is valid.
no sflow poller
Use this command to reset the sFlow poller instance to the default settings.
Format
no sflow sampler {<
rcvr-indx
> | rate <
sampling-rate
> | maxheadersize
<
size
>}
Mode
Interface Config
Format
sflow poller {<rcvr-indx> | interval <poll-interval>}
Mode
Interface Config
Field
Description
Receiver Index
Enter the sFlow Receiver associated with the sampler/poller. A value of zero (0) means
that no receiver is configured. The range is 1-8. The default is 0.
Poll Interval
Enter the sFlow instance polling interval. A poll interval of zero (0) disables counter
sampling. When set to zero (0), all the poller parameters are set to their corresponding
default value. The range is 0-86400. The default is 0. A value of N means once in N
seconds a counter sample is generated.
Format
no sflow poller {<rcvr-indx> | interval <poll-interval>}
Mode
Interface Config