12. On the Available Inventory page, select the node to add to the existing NetApp HCI installation.
For some compute nodes, you might need to enable EVC at the highest level your
vCenter version supports before you can add them to your installation. You should use
the vSphere client to enable EVC for these compute nodes. After you enable it, refresh
the Inventory page and try adding the compute nodes again.
13. Select
Continue
.
14. Optional: If you created a new vSphere datacenter cluster, on the Network Settings page, import network
information from an existing NetApp HCI deployment by selecting the
Copy Setting from an Existing
Cluster
checkbox.
This populates the default gateway and subnet information for each network.
15. On the Network Settings page, some of the network information has been detected from the initial
deployment. Each new compute node is listed by serial number, and you should assign new network
information to it. For each new compute node, perform the following steps:
a. If NetApp HCI detected a naming prefix, copy it from the Detected Naming Prefix field, and insert it as
the prefix for the new unique hostname you add in the Hostname field.
b. In the Management IP Address field, enter a management IP address for the compute node that is
within the management network subnet.
c. In the vMotion IP Address field, enter a vMotion IP address for the compute node that is within the
vMotion network subnet.
d. In the iSCSI A - IP Address field, enter an IP address for the first iSCSI port of the compute node that is
within the iSCSI network subnet.
e. In the iSCSI B - IP Address field, enter an IP address for the second iSCSI port of the compute node
that is within the iSCSI network subnet.
16. Select
Continue
.
17. On the Review page in the Network Settings section, the new node is shown in bold text. If you need to
make changes to information in any section, perform the following steps:
a. Select
Edit
for that section.
b. When finished making changes, select
Continue
on any subsequent pages to return to the Review
page.
18. Optional: If you do not want to send cluster statistics and support information to NetApp-hosted SolidFire
Active IQ servers, clear the final checkbox.
This disables real-time health and diagnostic monitoring for NetApp HCI. Disabling this feature removes the
ability for NetApp to proactively support and monitor NetApp HCI to detect and resolve problems before
production is affected.
19. Select
Add Nodes
.
You can monitor the progress while NetApp HCI adds and configures the resources.
20. Optional: Verify that any new compute nodes are visible in vCenter.