33
M16/M17 Cutting-gun descending on-off,M16(On)
,
M17(Off)
M24/M25 Preheat oxygen valve on-off,M24(On)
,
M25(Off)
M20/M21 Ignition on-off M20(on),M21(off)
M50
Preheat perforation fixed circle
, operate order as follow:
1.If acetylene valve isn’t opened, turn on acetylene ignition;
2.Cutting-gun descending(Cutting-gun descending delay, refer
M
71)
;
3.Open preheat oxygen valve, start preheat delay. If the time of preheat is not
enough, you can press
【
【
【
【
Pause
】
】
】
】
,
the preheat time will delay automatically 150 seconds.
If preheat is ok, you can press
【
【
【
【
Start
】
】
】
】
to finish preheat delay, and the pre-heat time will
be saved automatically to preheat delay parameter.
4.Cutting-gun rising (perforation cutting gun rising delay)
5.Open cutting oxygen valve, at the same time cutting-gun descending(perforation
cutting-gun delay) and start to run the latter program.
M51
Close cutting fixed cycle, opposite to M50. Operate order as follow:
1.Colse cutting oxygen valve(M13)
;
2.Cutting-gun rising (Cutting-gun rising delay, refer M70).
M51 is often used before G00, put up cutting-gun to shift position and avoid
colliding with steel plates.
M52
Ignition fixed cycle
, operate order: open acetylene valve(M10) and high-voltage
ignition(M20), delay “ignition delay”, close high-voltage ignition(M21).
M70
Cutting-gun rising fixed cycle
, operate order: open cutting-gun rising
on-off(M14),delay “cutting-gun rising delay”, close cutting-gun rising on-off(M15).
M71
Cutting-gun descending fixed cycle
, operate order: open cutting-gun descending
on-off (M16), delay “cutting-gun descending delay”, close cutting-gun descending
on-off (M17).
M80 General switch, after execute M80, all outputs will be closed.
M16/M17 Control output 4# on-off,M16(on),M17(off)
M18/M19 Control output 6# on-off,M18(on),M19(off)
M22/M23 Control output 7# on-off,M22(on),M23(off)
M40/M41 Control output 9# on-off,M40(on),M41(off)
M26/M27 Control output 10# on-off,M26(on),M27(off)
M28/M29 Control output 11# on-off,M28(on),M29(off)
M32/M33 Control output 12# on-off,M32(on),M33(off)
M34/M35 Control output 13# on-off,M34(on),M35(off)
M36/M37 Control output 14# on-off,M36(on),M37(off)
M38/M39 Control output 15# on-off,M38(on),M39(off)
M42/M43 Control output 16# on-off,M42(on),M43(off)
www.EngineeringBooksPdf.com