RBU
EN
• Check for dust or collected material inside the unit.
Dust or collected material may indicate a filter mal-
function.
7.2 Belt transmission
Perform the following belt transmission inspection
every 500 hours of operation:
1
Remove the belt guard, see
item 7.
2
Remove the motor side panel for easy access to
the screws that anchor the motor.
3
Replace worn or damaged belts and pulleys.
NOTE!
The lengths of the belts in the set must be
matched according to tolerances given in
ISO 4184.
4
Check the tension of the belt transmission and ad-
just if required. Use
as a guide for force F as
.
5
Put back the motor side panel.
6
Put back the belt guard.
NOTE!
New belts are liable to stretch slightly with-
in the first hours of use and are to be more
tightly tensioned than used belts.
RBU
1300
1600
1600E
2100
2100E
2600
2600
2600 FC
Hz
50–60
50–60
50
60
20–60
New belts F(N)
35
90
70
90
90
Used belts F(N)
25
60
45
60
60
7.3 Oil pump
Perform the following pump oil inspection every 500
hours of operation:
• Ensure that there is no oil leakage from the pump.
• Check the oil level.
• Check that the oil is clean.
7.4 Pump oil change
Remove the panels closest to the pump and the trans-
mission before changing oil.
The first oil change should be made after 500 hours
of use and then every 4000 hours of use. See the en-
closed pump manual for details regarding oil and oil
change. Oil change must be made on both sides of the
pump.
Fill in the back of the ‘Red card’ with information after
each oil change. Some pumps have an oil draining kit
with a hose which makes the oil change easier, see
.
NOTE!
The protection cap must only be tightened by
hand after the oil change, see
wise, the entire drain device might loosen the
next time the cap is removed. This ruins the
thread seal resulting in oil leakage and the en-
tire drain device must be replaced.
7.5 Internal cleaning
Perform the internal cleaning inspection every 500
hours of operation.
1
Turn off the unit.
2
Rotate the pump and motor by hand in both direc-
tions.
• If the pump and motor are hard to rotate the
pump may require internal cleaning. Contact
your local Nederman representative for this ser-
vice.
• If the pump and motor are easy to rotate the
pump does not require internal cleaning.
NOTE!
Never dismantle the pump. Special equipment
and knowledge are absolutely necessary for
re-assembling the pump. Assembling the pump
without this equipment results in severe dam-
age to the pump at the next startup.
7.6 Discharge silencer
Check the large silencer underneath the pump and
motor for cracks every 500 hours of operation. Re-
place the silencer if any cracks are found.
7.7 Thermal fuse
Never run the unit without a functioning thermal fuse
or temperature sensor installed. Contact your loc-
al Nederman representative in order to remedy the
cause and take necessary action if the pump temper-
ature exceeds 140°C. The fuse must only be replaced
22
Содержание RBU 1300
Страница 2: ...RBU Trace back information Workspace Main version a67 Checked in 2022 10 17 Skribenta version 5 5 022...
Страница 8: ...RBU Figures 5 6 11 12 13 8 4 9 3 7 10a 18 14 15 16 17 2 1 10b 1 8...
Страница 11: ...RBU 6 7 10 mm 0 39 8 11...
Страница 12: ...RBU Nm h kPa 9 Nm h kPa A A 10 12...
Страница 210: ...RBU RU 7 7 220 7 8 220 7 9 220 7 10 220 7 11 220 7 11 1 220 7 12 221 8 221 8 1 221 9 221 10 B 222 11 B 224 210...
Страница 211: ...RBU 1 Nederman Nederman Group Nederman Nederman EC Nederman Nederman Nederman 2 2 1 2 2 RU 211...
Страница 214: ...RBU RU 500 3 3 5 5 214...
Страница 218: ...RBU RU 6 2 6 2 1 1 2 1 2 3 a b 4 4 6 2 2 Y D Y D D Y Y D D 6 2 3 7 10 6 2 4 3 15 3 6 7 11 6 2 5 6 3 20 60 U f 7 2 218...
Страница 222: ...RBU RU 10 B 4 4 4 2 3 6 4 1 3 2 5 1 4 2 5 2 3 2 3 2 5 222...
Страница 223: ...RBU 5 3 5 3 ISO 8573 1 5 5 3 5 3 5 3 6 2 6 2 6 2 6 2 Y 6 2 D 6 2 6 2 RU 223...
Страница 224: ...RBU RU 11 B 7 1 7 1 5 1 7 2 7 2 7 2 7 3 7 4 7 5 7 12 Nederman 7 9 7 9 224...
Страница 225: ...RBU 7 8 7 10 7 10 7 11 7 7 7 6 RU 225...
Страница 242: ...RBU ZH 7 7 250 7 8 250 7 9 250 7 10 250 7 11 250 7 11 1 250 7 12 250 8 250 8 1 250 9 250 10 A 251 11 B 253 242...
Страница 243: ...RBU 1 Nederman Nederman Nederman Nederman EC Nederman Nederman Nederman 2 2 1 2 2 ZH 243...
Страница 251: ...RBU 10 A 4 4 4 2 3 6 4 1 3 2 5 1 4 2 5 2 3 2 3 2 5 5 3 5 3 ISO 8573 1 5 5 3 5 3 ZH 251...
Страница 252: ...RBU ZH 5 3 6 2 6 2 6 2 6 2 Y 6 2 D 6 2 VFD 6 2 252...
Страница 253: ...RBU 11 B 7 1 7 1 5 1 7 2 7 2 7 2 7 3 7 4 7 5 7 12 Nederman 7 9 7 9 7 8 7 10 7 10 7 11 7 7 ZH 253...
Страница 254: ...RBU ZH 7 6 254...
Страница 255: ...www nederman com...