8.5.4.2
Limiter operation
In the quadratic case two linear limiters are combined to operate as one quadratic
limiter, called limiter 1 and limiter 2. The registers are
•
DRW1START, DRW1XADD, DRW1YADD
•
DRW2START, DRW2XADD, DRW2YADD
See below figure for details about this. The grey box is an addition that does
different operation as in the linear setup. It is possible to drive the limiters in a
threshold modus. Then all values above 0 are considered 1. This is used in case
antialiasing is not desired.
Note
In the below diagram followign abbreviations are used:
•
start1 = DRWL1START, start2 = DRWL2START
•
xadd1 = DRWL1XADD, xadd2 = DRWL2XADD
•
yadd1 = DRWL1YADD, yadd2 = DRWL2YADD
x=0
y=0
xadd1=c+1,xadd2=2a
yadd1=d+1,yadd2=2b
start1=f,start2=xadd1
value1=start, value2=start2
output value1
x<width
x=x+1
value1=xadd1
value2=xadd2
y<height
y=y+1
start1=yadd1
start2=yadd2
End
Begin
yes
no
yes
xadd1=value2
Figure 8-12 Flowchart of quadratic limiter operation
Chapter 8
Drawing Engine
232
Preliminary User's Manual S19203EE1V3UM00
Содержание uPD72257
Страница 39: ...Pin Functions Chapter 2 Preliminary User s Manual S19203EE1V3UM00 39...
Страница 44: ...Chapter 2 Pin Functions 44 Preliminary User s Manual S19203EE1V3UM00...
Страница 46: ...Chapter 2 Pin Functions 46 Preliminary User s Manual S19203EE1V3UM00...
Страница 49: ...Pin Functions Chapter 2 Preliminary User s Manual S19203EE1V3UM00 49...
Страница 52: ...Chapter 2 Pin Functions 52 Preliminary User s Manual S19203EE1V3UM00...
Страница 54: ...Chapter 2 Pin Functions 54 Preliminary User s Manual S19203EE1V3UM00...
Страница 331: ...External Memory Interface Controller Chapter 9 Preliminary User s Manual S19203EE1V3UM00 331...
Страница 343: ......