Remote Inspection
• When Remote inspection is set to the terminal, “Confirm” and “Ring time” are displayed on the
Multiline Terminal LCD.
• If Remote inspection terminal is busy (receiving another incoming call or on call state), inspection
ring will start after previous call ends.
• When the terminal does not answer inspection ringing during the time assigned in PRG 20-45-03,
emergency calls will be placed to pre-programmed destination with pre-recorded VRS message.
• After finishing VRS message, destination person can start monitoring of inspection terminal. Also by
dialing
*
from outside it is possible to have a two-way conversation.
If you dial
*
while the message is being played, this will not enable the cut through. Dialing
*
during
the message stops the message from being played and you must dial
*
again to enable two-way
speech path.
When using Analog trunks, the destination person must dial
*
before the initial message is played to
the caller.
• If outgoing call restriction is set, the emergency call number must be pre-registered in the restriction
allow table, then emergency call can go through. Also even all trunk are busy, the call has high
priority and can go out.
• If destination does not answer the emergency call, the system repeatedly places the call for the
number of times specified in PRG 20-45-07.
• Maximum of 6 extensions can be set as Remote Inspection terminals.
• If all VRS channels are busy, tone will be provided instead of VRS message, such as for inspection
message or for destination message.
• If VRS message itself is not recorded, tone will be provided.
Emergency call destination MUST be set considering this feature’s purpose.
• The emergency number dialed does not follow ARS settings.
If PRG 13-01-01 is set to Trunk the system uses command PRG 13-05 to route the emergency call.
If PRG 13-01-01 is set to ICM the system uses command PRG 14-06 to route the emergency call.
• The VRS allows you to record up to 100 VRS messages (001-100). If you are using the built in VRS,
without the SD card, you can record all the incoming/outgoing messages within two hours message
storage.
Emergency Call 1
Emergency calls when “Security Sensor” or “Remote Inspection” performed, SMDR can record these
call class as follows.
• Security Sensor: SAD
• Remote Inspection: WAD
Emergency Call 2
Emergency calls when “Security Sensor” or “Remote Inspection” performed, alarm report can record
these alarm and alarm display terminal indicates following on LCD.
• Security Sensor: 31: Sensor Dial
• Remote Inspection: 32: Confirm dial
Recording Emergency Call
By setting PRG 90-20-11 (1; Report), Emergency calls can be recorded on security report.
• Maximum of 50 records can be saved.
ISSUE 1.0
SL2100
Features and Specifications Manual
1-753
S
Содержание UNIVERGE SL2100
Страница 1: ...Features and Specifications Manual GVT 010794 401 00 AU ISSUE 1 0 May 2017 ...
Страница 14: ...MEMO SL2100 ISSUE 1 0 R 4 Regulatory ...
Страница 53: ...Operation Depends on the connected ancillary device ISSUE 1 0 SL2100 Features and Specifications Manual 1 39 A ...
Страница 300: ...5 Press Speaker key to hang up SL2100 ISSUE 1 0 1 286 Distinctive Ringing Tones and Flash Patterns D ...
Страница 313: ...Operation None ISSUE 1 0 SL2100 Features and Specifications Manual 1 299 D ...
Страница 412: ...Operation None SL2100 ISSUE 1 0 1 398 Howler Tone Service H ...
Страница 446: ...Figure 1 19 Cascade Message Notification Flow Chart 1 SL2100 ISSUE 1 0 1 432 InMail Cascade Message Notification I ...
Страница 447: ...Figure 1 20 Cascade Message Notification Flow Chart 2 ISSUE 1 0 SL2100 Features and Specifications Manual 1 433 I ...
Страница 571: ...Operation LCR Operation Flow Diagram ISSUE 1 0 SL2100 Features and Specifications Manual 1 557 L ...
Страница 572: ...LCR Dial LCR Dial Editing SL2100 ISSUE 1 0 1 558 LCR Least Cost Routing L ...
Страница 573: ...LCR Cost Center Code ISSUE 1 0 SL2100 Features and Specifications Manual 1 559 L ...
Страница 604: ...On pressing OK the Cancel button is disabled as follows SL2100 ISSUE 1 0 1 590 Maintenance Automatic System Update M ...
Страница 728: ...2 Press the programmable key The programmed function displays SL2100 ISSUE 1 0 1 714 Programmable Function Keys P ...
Страница 846: ...2 Press Hold key and talk with the party SL2100 ISSUE 1 0 1 832 Tone Override T ...
Страница 878: ...Operation None SL2100 ISSUE 1 0 1 864 Universal Slots U ...
Страница 946: ...MEMO SL2100 ISSUE 1 0 1 932 Warning Tone for Long Conversation W ...
Страница 976: ...MEMO SL2100 ISSUE 1 0 3 6 Features Availability by Software Revision ...
Страница 977: ...MEMO ISSUE 1 0 SL2100 Features and Specifications Manual 3 7 ...
Страница 978: ...Features and Specifications Manual NEC Corporation ISSUE 1 0 ...