4.
Dial emergency call destination number “xxx-xxx” and press
Hold
key.
5.
Dial monitored terminal number, “200”.
6.
Dial VRS message number for destination answer, “002”.
7.
After beep tone, record the message.
8.
Press
Speaker
key and finish recording.
To start Security Sensor operation
1.
Press
Speaker
key + dial
719
+
1
at terminal, and sensor is valid after the timer (PRG 20-55-01)
passes.
- OR -
2.
Press the
Function
key (
*
33) at Multiline Terminal and Function key blinks.
The key lights after the timer (PRG 20-55-01) passes, and sensor is valid.
- OR -
3.
Security Sensor time pattern 1 comes time to start.
To stop Security Sensor operation
1.
Press
Speaker
key + dial
719
+
0
at terminal.
- OR -
2.
Press the red lit
Function
key (
*
33) at Multiline Terminal and the
Function
key turn off.
- OR -
3.
Security Sensor time pattern 1 comes time to stop.
When detect Security Sensor On
1.
Warning message send to internal page group1 and external page group 1.
2.
Place outgoing call automatically according to speed dial bin 999.
3.
When destination answered send VRS message 2.
4.
After finishing VRS message 2, destination person can monitor through extension 200. By dialing
*
from outside it is possible to make both way talk.
When send Warning message
When send Warning message, but does not place emergency call case:
PRG 20-46-05 is set table number, which has no setting.
When place emergency call
When place emergency call, but does not send Warning message case:
PRG 20-46-02 to PRG 20-46-03 should be set to “0”.
Room Monitoring from outside
< Program >
PRG 11-10-45: 610+1/0; Remote Monitor enable/disable.
PRG 13-04-01: Abbreviated Dial Data; set outside telephone number which makes room monitor.
PRG 13-04-03: 3; Transfer mode set “Remote monitor”.
PRG 13-04-04: 200; Set monitored terminal number.
PRG 15-07-01: Set “
#
03” to
Function
key.
ISSUE 1.0
SL2100
Features and Specifications Manual
1-759
S
Содержание UNIVERGE SL2100
Страница 1: ...Features and Specifications Manual GVT 010794 401 00 AU ISSUE 1 0 May 2017 ...
Страница 14: ...MEMO SL2100 ISSUE 1 0 R 4 Regulatory ...
Страница 53: ...Operation Depends on the connected ancillary device ISSUE 1 0 SL2100 Features and Specifications Manual 1 39 A ...
Страница 300: ...5 Press Speaker key to hang up SL2100 ISSUE 1 0 1 286 Distinctive Ringing Tones and Flash Patterns D ...
Страница 313: ...Operation None ISSUE 1 0 SL2100 Features and Specifications Manual 1 299 D ...
Страница 412: ...Operation None SL2100 ISSUE 1 0 1 398 Howler Tone Service H ...
Страница 446: ...Figure 1 19 Cascade Message Notification Flow Chart 1 SL2100 ISSUE 1 0 1 432 InMail Cascade Message Notification I ...
Страница 447: ...Figure 1 20 Cascade Message Notification Flow Chart 2 ISSUE 1 0 SL2100 Features and Specifications Manual 1 433 I ...
Страница 571: ...Operation LCR Operation Flow Diagram ISSUE 1 0 SL2100 Features and Specifications Manual 1 557 L ...
Страница 572: ...LCR Dial LCR Dial Editing SL2100 ISSUE 1 0 1 558 LCR Least Cost Routing L ...
Страница 573: ...LCR Cost Center Code ISSUE 1 0 SL2100 Features and Specifications Manual 1 559 L ...
Страница 604: ...On pressing OK the Cancel button is disabled as follows SL2100 ISSUE 1 0 1 590 Maintenance Automatic System Update M ...
Страница 728: ...2 Press the programmable key The programmed function displays SL2100 ISSUE 1 0 1 714 Programmable Function Keys P ...
Страница 846: ...2 Press Hold key and talk with the party SL2100 ISSUE 1 0 1 832 Tone Override T ...
Страница 878: ...Operation None SL2100 ISSUE 1 0 1 864 Universal Slots U ...
Страница 946: ...MEMO SL2100 ISSUE 1 0 1 932 Warning Tone for Long Conversation W ...
Страница 976: ...MEMO SL2100 ISSUE 1 0 3 6 Features Availability by Software Revision ...
Страница 977: ...MEMO ISSUE 1 0 SL2100 Features and Specifications Manual 3 7 ...