(b) When the value 0000H is set in GCCnm
INTCCGnm is activated when the value of the counter becomes 0001H.
INTTMGn0/INTTMGn1 is activated when the value of the counter changes from FFFFH to 0000H.
Note, however, that even if no data is set in GCCnm, INTCCGnm is activated immediately after the
counter starts.
(c) When the value FFFFH is set in GCCnm
INTCCGnm and INTTMGn0/INTTMGn1 are activated when the value of the counter changes from
FFFFH to 0000H.
(d) When GCCnm is rewritten during operation
When GCCn1 is rewritten from 5555H to AAAAH. TMGn0 is selected as the counter.
The following operation is performed:
Figure 10-45:
Timing when GCCn1 is rewritten during operation (free run)
Caution:
To perform successive write access during operation, for rewriting the GCCny
register (n = 1 to 4), you have to wait for minimum 7 peripheral clocks periods (f
PCLK
).
Match
Match
5555H
AAAAH
AAAAH
5555H
Reload in 5 periods
INTCCGn1
TMGn0
ENFG0
f
PCLK
GCCn1 Slave register
GCCn1 Master register
Содержание mPD703128
Страница 6: ...6 Preliminary User s Manual U15839EE1V0UM00 ...
Страница 20: ...20 Preliminary User s Manual U15839EE1V0UM00 ...
Страница 32: ...32 Preliminary User s Manual U15839EE1V0UM00 MEMO ...
Страница 154: ...154 Preliminary User s Manual U15839EE1V0UM00 MEMO ...
Страница 238: ...238 Preliminary User s Manual U15839EE1V0UM00 MEMO ...
Страница 356: ...356 Preliminary User s Manual U15839EE1V0UM00 MEMO ...
Страница 522: ...522 Preliminary User s Manual U15839EE1V0UM00 MEMO ...
Страница 600: ...600 Preliminary User s Manual U15839EE1V0UM00 MEMO ...
Страница 610: ...610 Preliminary User s Manual U15839EE1V0UM00 ...
Страница 612: ......