344
Chapter 10
Timer
Preliminary User’s Manual U15839EE1V0UM00
(d) When a value exceeding the value set in GCCn0 or GCCn5 is set in GCCnm (match and
clear)
When a value exceeding the value set in GCCn0 (GCCn5) is set in GCCnm, TOGnm starts and
continues outputting the active level immediately after the first match and clear event (until count
operation stops.)
The figure shows the state of TOGn1 when 0FFFH is set in GCCn0, 1FFFH is set in GCCn1, and
TMGn0 is selected.
Figure 10-56:
Timing when the value of GCCnm exceeding GCCn0 or GCCn5
(match and clear)
Low
ENFG0
TMGn0
GCCn1
INTCCGn1
INTCCGn0
0FFFH
0FFFH
0FFFH
1FFFH
TOGn1(ALVG1=0)
TOGn1(ALVG1=1)