511
Chapter 14
FCAN Interface Function
Preliminary User’s Manual U15839EE1V0UM00
Regarding the maximum sampling point setting and the resulting sampling point, two settings meet all
the requirements above. Therefore the correct settings are:
(1)
TLM=0:
BRP5 to BRP0
= 000101B
(5)
(prescaler BRP = 12 TQ)
DBTR4 to DBTR0 = 01111B
(15)
(data bit time DBT = 16 TQ)
SPTR4 to SPTR0 = 01100B
(12)
(sampling point SPT = 13 TQ)
or
BRP5 to BRP0
= 000111B
(7)
(prescaler BRP = 16 TQ)
DBTR4 to DBTR0 = 01011B
(11)
(data bit time DBT = 12 TQ)
SPTR4 to SPTR0 = 01000B
(8)
(sampling point SPT = 9 TQ)
(2)
TLM=1:
BRP7 to BRP0
= 00001011B
(11)
(prescaler BRP = 12)
DBTR4 to DBTR0 = 01111B
(15)
(data bit time DBT = 16 TQ)
SPTR4 to SPTR0 = 01100B
(12)
(sampling point SPT = 13 TQ)
or
BRP7 to BRP0
= 00001111B
(15)
(prescaler BRP = 16)
DBTR4 to DBTR0 = 01011B
(11)
(data bit time DBT = 12 TQ))
SPTR4 t oSPTR0 = 01000B
(8)
(sampling point SPT = 8 TQ)
Содержание mPD703128
Страница 6: ...6 Preliminary User s Manual U15839EE1V0UM00 ...
Страница 20: ...20 Preliminary User s Manual U15839EE1V0UM00 ...
Страница 32: ...32 Preliminary User s Manual U15839EE1V0UM00 MEMO ...
Страница 154: ...154 Preliminary User s Manual U15839EE1V0UM00 MEMO ...
Страница 238: ...238 Preliminary User s Manual U15839EE1V0UM00 MEMO ...
Страница 356: ...356 Preliminary User s Manual U15839EE1V0UM00 MEMO ...
Страница 522: ...522 Preliminary User s Manual U15839EE1V0UM00 MEMO ...
Страница 600: ...600 Preliminary User s Manual U15839EE1V0UM00 MEMO ...
Страница 610: ...610 Preliminary User s Manual U15839EE1V0UM00 ...
Страница 612: ......