Chapter 10
Timer
Preliminary User’s Manual U15839EE1V0UM00
10.1.5 Operation
(1)
Count operation
Timer C can function as a 16-bit free-running timer.
When it operates as a free-running timer and the CCC00 register or CCC01 register and the
TMC0 count value match, an interrupt signal is generated and the timer output signal (TOC0) can
be set or reset.
Also, a capture operation that holds the TMC0 count value in the CCC00 or CCC01 register is
performed, synchronized with the valid edge that was detected from the external interrupt request
input pin as an external trigger. The capture value is held until the next capture trigger is
generated.
Figure 10-8:
Timing of basic operation of Timer C
0001H
0000H
0002H 0003H
FBFEH FBFFH
0001H 0002H
0000H
TMC0
COUNT
Count disabled
CE 0
Count start
CE 1
Count start
CE 1
←
←
←
f