1. POST Error Message
Express5800/T120e Maintenance Guide
127
Chapter 3 Appendix
(3) Error messages on a virtual LCD
You can confirm the error messages by the EXPRESSSCOPE Engine 3 web browser window. See
"
EXPRESSSCOPE Engine 3 User’s Guide
" for details.
The table below shows the error messages displayed on upper and lower lines, cause, and solution.
Messages displayed on an upper LCD line
(1/2)
BIOS Message on
Upper LCD Line
Cause Solution
XX POST Started ...
Displayed while POST is running.
"XX" denotes POST code that is
running.
This is not an error.
XX BIOS Rev YYYY
Displayed while POST is running.
"XX" denotes POST code that is
running, and "YY" denotes system
BIOS version.
This is not an error.
POST Completed
Successfully
Displayed when POST completes
normally.
This is not an error.
POST ERROR XXXX
Error XXXX was detected during
POST.
Check the message displayed on LCD, and take
an appropriate action.
No Available
Memory in System
No available memory is
implemented.
Make sure that the memory is correctly
implemented.
Error Pause in POST
POST detected an error and paused. Check the message displayed on LCD, and take
an appropriate action.
Entering BIOS
SETUP MENU
Starting up BIOS SETUP MENU.
This is not an error. This message will disappear
when SETUP operation is completed.
Waiting for normal
temperature
A temperature abnormality was
detected inside the server.
Lower the room temperature or turn off the
power to cool the server to room temperature
before starting up the server. If this abnormality
continues to occur, check if a fan has failed. If
the same error still continues to occur, contact
your sales representative.
Message displayed on
upper LCD line
Message sent from BIOS
Message displayed on lower
LCD line
Message sent from BMC