1. POST Error Message
Express5800/T120e Maintenance Guide
125
Chapter 3 Appendix
(7/7)
Error Message
Cause
Solution
C300
Out-of-band setup
configuration failure
Configuration change requested
by remote terminal via network
failed.
Unplug the power cord, wait for at least 30 seconds,
then restart the server. If the same error is detected
repeatedly, contact your sales representative.
C301
SDR mismatch error
Inconsistency in the hardware
information of the sensor data
record was detected
C302
Hardware configuration
error.
Illegal hardware configuration
was detected.
C310
Hardware configuration of
cooling is insufficient.
Detected that cooling power is
insufficient in this hardware
configuration.
Contact your sales representative.
C320 Unmatched
PSUs.
Unmatched power supply units
are configured.
C321
System power consumption
is out-of-range in PSUs.
System power consumption
exceeds the power output
capacity limit.
C322
No information for system
power consumption check.
No information is acquired in
checking system power
consumption.
Check the installation status of power supply units.
Unplug the power cord, wait for at least 30 seconds,
then restart the server. If the same error is detected
repeatedly, contact your sales representative.
C501
Intel Node Manager is in
Recovery Mode.
Intel Node Manager is in
Recovery Mode.
Unplug the power cord, wait for at least 30 seconds,
then restart the server. At that time, check the jumper
switch setting on motherboard.
If the same error is detected repeatedly, contact your
sales representative.