NX50 Troubleshooting Manual
Responding to alarms
Issue 6.0 2019-04-01
Page 1-3
It is recommended that the transmitter’s output be connected to a precision 50
resistive
dummy load (rated for 1.5 times the rated transmitter carrier power) before starting off-air
troubleshooting procedures. If an appropriate dummy load is not available, troubleshooting
for a majority of faults can be performed with the RF power stage turned off. The transmitter
may remain connected to its antenna system for these procedures.
Electrostatic protection
The transmitter's assemblies contain semiconductor devices that are susceptible to damage
from electrostatic discharge. The following precautions must be observed when handling an
assembly which contains these devices.
Electrical discharging of personnel
Personnel should be electrically discharged by a suitable grounding system (e.g., anti-static
mats, grounding straps) when removing an assembly from the transmitter, and while handling
the assembly for maintenance procedures.
Handling/Storage
An assembly should be placed in an anti-static bag when it is not installed in a host transmitter,
or when it is not undergoing maintenance. Electronic components should be stored in anti-
static materials.
Tools/Test equipment
Testing and maintenance equipment – including soldering and unsoldering tools – should be
suitable for contact with static sensitive semiconductor devices.
NOTE:
Reduce the RF output level to a minimal value when troubleshooting faults in
the power amplifier stage while the transmitter’s RF output is connected to the
antenna system.
CAUTION:
Electrostatic energy is produced when two insulating materials are rubbed
together. A person wearing rubber-soled shoes, walking across a nylon carpet or a
waxed floor, can generate an extremely large electrostatic charge. This effect is
magnified during periods of low humidity. Semiconductor devices such as
integrated circuits, field-effect transistors, thyristors and Schottky diodes may be
damaged by this high voltage unless adequate precautions are taken.
Содержание NX50
Страница 1: ...NX50 Transmitter Troubleshooting Manual Document NHB NX50 TRB Issue 6 0 2019 04 01 Status Standard...
Страница 2: ......
Страница 4: ......
Страница 8: ...NX50 Troubleshooting Manual Page viii Issue 6 0 2019 04 01...
Страница 10: ...NX50 Troubleshooting Manual Page x Issue 6 0 2019 04 01...
Страница 108: ...NX50 Troubleshooting Manual Responding to alarms Page 1 98 Issue 6 0 2019 04 01...
Страница 153: ...NX50 Troubleshooting Manual Reading Electrical Schematics Page 4 6 Issue 6 0 2019 04 01...
Страница 184: ...Issue 6 0 2019 04 01 MD 4 Figure MD 4 NAPI95A 01 Power Module Interface PWB...
Страница 188: ...Issue 6 0 2019 04 01 MD 8 Figure MD 8 NAPI106 Remote Interface PWB...
Страница 192: ...Issue 6 0 2019 04 01 MD 12 Figure MD 12 NAPI98 RF Drive Distribution PWB...
Страница 194: ...Issue 6 0 2019 04 01 MD 14 Figure MD 14 NAX243B 01 B Distribution Assembly J1 R1 R2 R3 R4 Front View Rear View...
Страница 198: ...Issue 6 0 2019 04 01 MD 18 Figure MD 18 Fan Tray Assembly 207 8133 B1 B2 J1 AIR FLOW AIR FLOW...
Страница 200: ...Issue 6 0 2019 04 01 MD 20 Figure MD 20 Current Probe 207 6213 10 Front View Rear View T1 R1 R2 R3 R4 J1 P1...
Страница 201: ...Issue 6 0 2019 04 01 MD 21 Figure MD 21 NAFP106B 01 Directional Coupler A1 DETAIL...
Страница 204: ......