32
ingly. The Emergency Command will NOT be sent to the Gateway and therefore will NOT be sent to other
locks in the system.
TIP:
Combining Global and Local Features:
You can combine the various Global and Local Emergen-
cy features to customize your system.
Example #1:
DL-Windows by default enables (checks) all of the features, as shown above in the
Features
dialog.
What will happen when all features are enabled and an "
Emergency Lock Down
" command is initiated from a
keyfob? Because the
Activate Local Emergency
commands are enabled, the lock that receives and initiates the
Emergency Command will lock down, then the lock will inform the Gateway to broadcast the Emergency Com-
mand to all locks assigned to the same "
Gateway Group
".
Example #2:
This example is known as the " pull station option" , where the
Activate Global Emergency
command is checked, the
Activating Local Emergency
command is not checked, and the "
Lock Responds to Glob-
al Emergency Commands
" is unchecked. If an "
Emergency Lock Down
" command is then initiated, the
lock will first inform the Gateway to broadcast the Emergency Command to all locks assigned to the same
"
Gateway Group
" , then the lock will ignore the broadcast when received.
Emergency Users
Activating Emergency Commands
By default, Administrative Users (Users 1 through 11) automatically have the ability to initiate Emergency Commands
from the keypad. In addition, "Basic Users" (Users 12+) may be granted the ability to initiate Emergency Commands
from the keypad by adding them as Emergency Users in DL-Windows (for more information about adding Emergency
Users in DL-Windows, see OI383).
Note:
All paired Wireless Remote Releases have the ability to initiate Emergen-
cy Commands (see page 36 for more information).
Access During an Emergency
When enabled:
If the feature
Users are Disabled During Lockdown
is enabled (checked) for a specific
lock, and when the Networx system is in an Emergency Lock Down state, "Basic Users" (Users 12+) are denied
the ability to unlock the physical lock (credentials for these Basic Users are ignored). The proximity credentials
added as Administrative Users (Users 2 through 11), "Program Cards", Bluetooth credentials, as well as all
"Emergency Users"
remain enabled
, retaining the ability to unlock a secured lock.
When disabled:
If the feature
Users are Disabled During Lockdown
is disabled (unchecked) for a spe-
cific lock, and when the Networx system is in an Emergency Lock Down state, ANY valid credential that exists
in the lock's internal memory will be allowed to unlock the secured lock, regardless of User Number.
Emergency Alert Options
Sounder
If
Enable Sounder on Emergency
is enabled (checked), upon receiving an Emergency Command, the integral
sounder will beep once per second for 30 seconds.
Tip:
Only " Local" Emergency Commands are supported when using an
AL-IME-USB
Gateway . See page
4 for Gateway model descriptions.
Emergency Commands (cont'd)
When a User Code from an Administrative or Emergency User is pressed at any lock keypad, first the
lock unlocks, then the lock permits the use of the following Emergency Commands:
...press
911
to issue "
Emergency Lock Down
"
...press
000
to issue "
Emergency Passage
"
...press
123
to issue "
Return to Normal
"
[ _ _ _ _ ]
Administrative
or
Emergency User
Code