10
Remember:
The default state before and after power up is in passage (" unlocked" ). If you need to secure the door
("lock the lock"), perform the "
POWER UP
" and the "
SECURING THE DOOR
" procedures, below.
POWER UP
After physically installing your lock, you
must
perform the following "
POWER UP
" procedure for cor-
rect lock operation.
1. With the batteries disconnected,
press
and firmly
hold
the "
Program / Passage
" button for 15
seconds (button location dependent on model, see illustration at right).
2. Release the "
Program / Passage
" button and reconnect the batteries. Listen for a chirp and 3
beeps.
3. Press and hold the "
Program / Passage
" button again until you hear multiple beeps, then release
the button.
4. The lock will continue to beep and flash the red LED while residual programmed data clears and the lock initializes. A
final two beep/green flash sequence will occur, indicating successful completion of the power up procedure.
Note:
This
step can take up to 15 seconds.
At this point, by default the ArchiTech series lock is in passage ("unlocked") and is available for discovery by
any
Networx
Gateway and by DL-Windows for the next 24 hours.
WARNING:
Because
any
Gateway can discover (and thus con-
trol) the lock, we recommend not to power the lock until you either perform the "
SECURING THE DOOR
" procedure
(below) or perform the mode selection process (one of the options listed on page 9).
Note:
The lock will remain in pas-
sage indefinitely (even after several years and the batteries are drained) and will only re-lock upon the presentation and
acceptance of a valid credential
.
SECURING THE DOOR
("LOCKING THE LOCK")
The default state before and after power up is in passage ("unlocked"). If you need to secure the door ("lock the lock"), per-
form the "
POWER UP
" procedure (above) first, then use the keypad to perform all of the steps on this page, below:
Enter "Program Mode" and Change Factory Master Code
1. Press the default Master Code:
1
2
3
4
5
6
.
2. Wait for the green light and press and hold
;
until multiple beeps are heard. You are
now in "Program Mode".
Note:
The lock will beep every 6 seconds as a reminder that you
are in "Program Mode".
3. Enter a new personal 6-digit Master Code number by pressing the following keys:
;
1
;
[new Master Code]
;
[new Master Code]
:
(the second set of
digits must be exactly the same).
(For example, if you want your new Master Code to be "664433". Press:
;
1
;
664433
;
664433
:
).
Now that the Master Code has been changed, there is no need to change it again (unless you want to).
Add a User Code
4. Press
;
2
;
1
2
;
[press a new 3-6 digit User Code]
:
.
Since you are still in Program Mode, you can repeat step 4 and add another User Code.
5.
Exit Program Mode:
Hold down any key until you hear multiple beeps. The lock is
now in "normal" mode (i.e. the lock is now "in use").
Note:
If no keys are pressed when in
Program Mode, the lock will exit Program Mode after 3 minutes. A steady tone will sound for
the final 15 seconds of the 3 minute timeout period as a warning . To remain in Program Mode, simply press any key.
6.
Secure the door!
There's one final step: Simply press the new User Code that you added in step 4. Listen for
the lock mechanism to cycle (it's already unlocked), then after 3 seconds listen for the lock to lock.
Congratulations!
The door is secured, and will remain secured indefinitely until acted upon.
Note:
Be aware the new User Code added in step 4 is residing in User Number 12 (see page 5 for the definition
of "User Number". Simply be aware of this information, as it may become relevant later.
Power Up and Secure the Door
MORTISED
NETWORX CONTROL
UNIT
SURFACE-MOUNTED
NETWORX
CONTROL UNIT
"PROGRAM / PASSAGE" BUTTON
If you wish, write
your new 6-digit
Master Code here:
_ _ _ _ _ _
If you wish, write
your new 3-6 digit
User Code here:
_ _ _ _ _ _