38
Erase All Programming (Restore the "out of box" factory condition)
To return the ArchiTech series lock to its original condition, when the lock and all components were first removed
from their factory packaging, proceed as follows for the specific model type in your installation:
To erase all programming in the
Mortised Networx Control Unit
:
1. Remove the two 8-32 x 1/4" Phillips Flat-Head screws that secure the flush
Fin-
ishing Plate
that covers the
Mortised Networx Control Unit
. Put screws
aside in a safe place.
2. The
Finishing Plate
is connected to the internal PC board with a wire (take note
of how the wire is placed under the PC board at the factory). Gently lift and
move the
Finishing Plate
to the side.
3. Pull out the battery connector wires and disconnect the plugs.
4. Press and hold the "
Program / Passage
" button (see arrow in image at right) for
15 seconds, then release.
5. Reconnect the battery connector plug. Listen for 3 beeps. Press and firmly hold
the "
Program / Passage
" button again until you hear multiple beeps, then re-
lease the button. The lock will continue to beep and flash the red LED while re-
sidual programmed data clears and the lock initializes. A final 2 beep/green
flash sequence will occur, indicating successful completion of the power up pro-
cedure.
Note:
This step can take up to 15 seconds.
6. Gently push the battery wires (and any other loose wires) back into the
Control Unit
.
7. Return the
Finishing Plate
to its original location and secure with the two 8-32 x 1/4" Phillips Flat-Head screws.
To erase all programming in the
Surface-Mounted Networx Control Unit
:
1. Using the supplied Allen key, remove the mounting screw located in the previous step (#6-32 Allen Head coun-
tersunk U-cut Dog Point screw, part #SC681, shown at right). Put screw aside in a
safe place.
2. Lift the bottom of the
Surface-Mounted Networx Control Unit
and unhook
the top. Gently lift from the door surface; do not pull wires. It is OK to let the
unit "hang" from the door.
3. With two fingers, firmly grasp the battery wires connected to the white plug.
Pull the wires until the plug releases from the white female socket. It is OK to use
some force in this step.
4. Press and hold the "
Program / Passage
" button (see arrow in image at right) for 15
seconds, then release.
5. Re-insert the white battery plug into the white socket and press firmly until secure.
Listen for 3 beeps. Press and firmly hold the "
Program / Passage
" button again until
you hear multiple beeps, then release the button. The lock will continue to beep and
flash the red LED while residual programmed data clears and the lock initializes. A
final 2 beep/green flash sequence will occur, indicating successful completion of the power up procedure.
Note:
This step can take up to 15 seconds.
6. Ensure all wires are pushed back into the door to avoid pinching wires. Carefully hook the top of the
Surface-
Mounted Networx Control Unit
into the top of the
Control Unit Mounting Plate
(see installation instruc-
tions if necessary) and press the bottom until flush with the door surface. Replace the #6-32 Allen Head coun-
tersunk U-cut Dog Point screw (part #SC681 as shown above) at the bottom of the
Surface-Mounted Networx
Control Unit
and tighten securely. Replace all hardware removed as required.
Erase All Programming
MORTISED
NETWORX CONTROL UNIT
SURFACE-MOUNTED
NETWORX
CONTROL UNIT