background image

Three Ways to Program  

Adding keypad buttons to the proximity reader allows for additional programming options:  



"Program Card Programming": 

 For " stand-alone" operation, without enrollment into a Networx (DL-Windows) sys-

tem.  Create special proximity "Program Cards" at the lock's Proximity Reader, then use these "Program Cards" to 
create new proximity credentials for distribution.   



"Keypad Programming":

  Programming using the keypad.  After setting your unique " Master Code" , add a Us-

er Code (be aware that only a User Code can lock the lock; see page 10, "

SECURING THE DOOR

", step 6), set the 

Date, Time, and Weekday, add credentials and program other functions described starting on page 14.  Keypad Pro-
gramming can be used "stand-alone" or after enrollment into a Networx system.   



DL-Windows Mode:  Full Administrative programming 

from a PC using Alarm Lock's DL-Windows Software.  For 

a description of all features, see the 

DL-Windows User's Guide

 (OI382) and the 

DL-Windows for Networx User's Guide

 

(OI383).  There are two ways to use DL-Windows: 



Networked mode

:  PC running DL-Windows is connected to (wirelessly or wired) a network, either using an Ether-

net or 802.11 connection.  Communications are accomplished through networked Gateway module(s).  See page 4 
for supported products. 



Non-networked mode

:  PC running DL-Windows does not require a network.  Communications are accomplished 

using an 

AL-IME-USB

 Gateway inserted into a USB port on your Windows laptop or PC.  

Note:

  Only " Local"  

Emergency Commands are supported when using an 

AL-IME-USB

 Gateway.  See page 4 for supported prod-

ucts. 

 

Audit Trail 



40,000 Event Capacity (see OI382) 



Entries Logged with Time and Date (see OI382) 



Critical Programming Events Logged (see OI382) 



Door position logging capability (see "Features" Screen in OI382) 



Up-loadable using Alarm Lock's DL-Windows Software (see OI382 and OI383) 

 

Lock Features 



Metal Key Override for all cylindrical locks 



Non-Volatile (Fixed) Memory 



Real-Time Clock, with Automatic Daylight Saving Time Adjust (see OI382) 



Visual and Audible Feedback (see chart on page 40) 



Integrated Door position switch (see "

Door Contact Sensor

" on page 8)  



Uses four Standard AA Batteries, with Low Battery Warning indication (see chart on page 37)  

 

Scheduling (Using DL-Windows) 



500 Scheduled Events (see OI382) 



Automated Unlock / Lock (see OI382) 



Enable / Disable Users (see page 5 for definition of "User") 



Enable / Disable Groups (see page 6 for definition of "Group") 



Real-Time Clock and Calendar (see OI382 and OI383) 



Power Saving Mode:

  Turns radio off to prolong battery life (see page 30) 



Bluetooth ON/OFF scheduling via DL-Windows (see page 33)*  

 

User Access Methods 



Keypad-entered User Codes  



Works with Multiple Proximity Access Credential Technologies (125kHz Format, 13.56MHz Format depending on model), including 
Proximity Cards, Proximity "Fobs", RR-1BUTTON 

Wireless Remote Release Button

 (see WI1999) and the RR-4BKEYFOB 

Wireless 

Remote Release Keyfob

 (WI2004) 



Manual Card Enrollment Option for "Program Card Programming" Installation (see page 11) 



Bluetooth LE access via iLock

 Smartphone app (see page 34)* 

 

User Features

 



Supports up to 5000 Key-free Users (see "

What is a User?

" on page 5) 



Service Credential (see "

User 300: One-Time-Only Service Credential

"  on page 6) 



Guard Tour (see "

User 298 and User 299: Guard Tour

" on page 6) 



Users Assignable to 4 Groups (see "

What is a Group?

" on page 6) 



Global Lock-Down / Unlock in emergency; activated from 

Wireless Remote Release 

Transmitters, DL-Windows or initiated from another 

Networx lock in the system (see page 31) 

 
Wireless programming range:  Up to 200 feet, depending on building construction materials. 

ArchiTech

 Features 

*For ArchiTech models equipped with Bluetooth LE technology. 

 

 

Содержание Networx ArchiTech

Страница 1: ...RD DL WINDOWS PROGRAMMING SOFTWARE ArchiTech by Networx with Keypad ProxReader USER S GUIDE NAPCO Security Technologies Inc 2018 OI410LF 8 18 RR 1BUTTON WIRELESS REMOTE RELEASE AL PRE PROXIMITY CREDEN...

Страница 2: ...t Program Card Programming Operation 11 12 Keypad Programming Overview of Functions 13 Keypad Programming Conventions 14 Keypad Programming Functions 14 25 Keypad Programming Record Sheet 26 Keypad Pr...

Страница 3: ...ability see Features Screen in OI382 Up loadable using Alarm Lock s DL Windows Software see OI382 and OI383 Lock Features Metal Key Override for all cylindrical locks Non Volatile Fixed Memory Real Ti...

Страница 4: ...nd consequently can control the devices in the system Note Version 2 Gateways are the second generation of Networx wireless Gateways ArchiTech door locks are still compatible with Version 1 Gateways S...

Страница 5: ...1 PM and lock again at 5 PM every week Terminology Used in this Manual day See next page for the definition of Group In DL Windows use the Schedule TimeZone screen to first create an individual block...

Страница 6: ...ystem can be used to disseminate these com mands to all locks in the network Who are Users 297 300 Credentials assigned to User Numbers 297 298 299 and 300 have special abilities as follows Terminolog...

Страница 7: ...ministrative Users Programming ability able to place lock into Enroll Mode and to enroll additional Basic User credentials or a Wireless Remote Release Emergency User during an Emergency state credent...

Страница 8: ...Door Contact Sensor The Door Contact Sensor is required to monitor the position of the door open or closed The Door Contact Sensor is shown above at right note also that a Sensor is integrated within...

Страница 9: ...Program Mode and make changes to the lock programming Once the new Master Code is set then you can program other things using the keypad such as setting the weekday date and time After this you can s...

Страница 10: ...use the keypad to perform all of the steps on this page below Enter Program Mode and Change Factory Master Code 1 Press the default Master Code 1 2 3 4 5 6 2 Wait for the green light and press and hol...

Страница 11: ...2 short confirmation beeps 3 Present the second proximity card to the Proximity Reader Again listen for 2 short confirmation beeps If the second card is not enrolled within the 30 second time out sim...

Страница 12: ...d the Program Passage button for 4 seconds until you hear a series of beeps Exit Enroll Mode indication All added credentials are considered Basic Users i e no programming abilities cannot enter Enrol...

Страница 13: ...nction 45 46 Passage Mode Enable Disable See page 19 Function 47 Reserved Keypad Programming Overview of Functions Function 48 Enable Passage Mode See page 20 Function 49 Disable Passage Mode See page...

Страница 14: ...edential to reader within 10 seconds User Number Entering a User Code PIN No Code into the lock programming Programming Key Sequence Programming Information General Program Mode Information If a wrong...

Страница 15: ...amples regarding special Users 297 300 9 9 Enable User 300 Service Code 1 0 0 0 0 10 Erase All Users Except the Master Code User 1 This Function enabled through keypad only Erases all User Codes excep...

Страница 16: ...Function only disables the timeout the event associated with the timeout will remain 3 CLEAR FUNCTIONS Group Enable Disable Enter the functions below to Enable Disable Groups Functions 14 23 will eac...

Страница 17: ...Group associations for User 67 Enter 3 5 6 7 NOTE If a User is associated with more than one Group all associated Groups would have to be disabled before the User is disabled 3 36 Reserved Clear All...

Страница 18: ...nds at 2AM on the programmed date Enter 4 1 0 0 0 to disable DST All locks leave the factory with DST enabled and pre programmed to the following start and end dates for the USA beginning 2007 Default...

Страница 19: ...al 10 seconds then program 20 seconds using Function 43 Example 1 Clock is losing 13 seconds every day enter 4 3 1 3 This example assumes that the Clock Adjust setting was at the factory default of ze...

Страница 20: ...he Pass Time expires the lock will re lock automati cally Use the functions below to change the Pass Time to 3 10 or 15 seconds The Pass Time is defaulted to 3 seconds Note Compare to Function 55 Enab...

Страница 21: ...of the default program Remote Input Wireless Remote Release Pairing 6 5 65 Enable Remote Input 2 REMOTE INPUT 6 5 ____ Slot Number 1 10 65 Pair Wireless Remote Release Note In addition to using a wire...

Страница 22: ...n programmed a Group 3 User is allowed entry only once then be comes disabled Note When the credential is entered for the first time and access is granted the Event Log will show Entry followed by Use...

Страница 23: ...be set ON to enable Forced Door Detection 56 Automatic Deadbolt No Passage Override Enable when automatic deadbolt hardware is used Note Be aware of the following terminology when reading the descript...

Страница 24: ...ll go into a locked state Presumably the user will be inside the premises but does not need to be if the user chooses to remain outside the premises during the second deadbolt extension a valid creden...

Страница 25: ...ay 6 for Friday 7 for Saturday 8 for Monday to Friday 9 for Saturday and Sunday and 0 for all days of week 3 72 Schedule Enable Passage Mode Unlock 7 2 _ _ _ _ _ Day Time 73 Schedule Disable Passage M...

Страница 26: ...eet 24 One Time Entry for Group 3 Users 25 Disable Sounder 29 Toggle Passage Mode 36 Cancel Passage on Button Press 38 Lock Responds to Global Emergency Commands 39 Users are Disabled During Lockdown...

Страница 27: ...ogrammed For the Day enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday through Friday 9 Saturday and Sunday 0 All days of the week Enter time of day in 24 hour form...

Страница 28: ...ID card An example N95I2 Lock Type selection is shown below Note Correct Lock Types are required for successful ly linking a physical lock to the DL Windows Lock Pro file see What is a Lock Program o...

Страница 29: ...ress etc will be sustained indefinitely until cancelled via a lock Schedule or subsequent Program Passage button press Enable One Time Entry option Used with the above described Automatic Deadbolt fun...

Страница 30: ...ies lock is installed inside a business office where the office closes and remains empty at night a Schedule can be created to place the ArchiTech series lock into a Power Saving Mode from 5 05 PM thr...

Страница 31: ...he documentation that came with it and also the Wireless Remote Releases section on page 36 Receiving Emergency Commands Lock Responds to Global Emergency Com mands When enabled The lock WILL accept a...

Страница 32: ...ers in DL Windows for more information about adding Emergency Users in DL Windows see OI383 Note All paired Wireless Remote Releases have the ability to initiate Emergen cy Commands see page 36 for mo...

Страница 33: ...Card OR any Administrative User 2 11 with the state of the lock unlocked press Program Passage button once 3 Within 30 seconds tap Add a New Lock on the iLock app 4 In the Select Lock screen select th...

Страница 34: ...page 7 Battery Indicates the latest percentage of remaining usable ca pacity of the battery in the selected lock updated upon each successful communication Important The per centage will equal zero up...

Страница 35: ...series lock The lock will unlock within a few seconds this time varies with smartphone models Red padlock turns green upon unlock and remains green unlocked for the duration of the programmed Pass Ti...

Страница 36: ...Wireless Remote Release button you wish to pair Selecting a button in advance will greatly assist this process Keep the Wireless Remote Release in your hand as you perform the next steps 2 Place the A...

Страница 37: ...n the Finishing Plate to its original location and secure with the two 8 32 x 1 4 Phillips Flat Head screws To replace batteries in the Surface Mounted Networx Control Unit 1 Using the supplied Allen...

Страница 38: ...nted Networx Control Unit 1 Using the supplied Allen key remove the mounting screw located in the previous step 6 32 Allen Head coun tersunk U cut Dog Point screw part SC681 shown at right Put screw a...

Страница 39: ...l Unit installed however DO NOT touch the Program Passage button AT ANY TIME during the procedure If the lock is powered down for an extended period of time and if you do not hear 3 beeps when power i...

Страница 40: ...exit Sounder ca dence longer for exiting Enroll Mode compared with entering Waiting for credential in Enroll Mode Rapid Green for 25 seconds then Red for final 5 seconds Rapid beeps for entire 30 seco...

Страница 41: ...41 User Card Record Sheet NAME OF DOOR DEPARTMENT EMBOSSED NUMBER ON CARD USER NAME LAST FIRST DATE ACTIVATED COMMENTS Page ______...

Страница 42: ...tory condition when the device was first taken out of its box With an ArchiTech lock its default settings are per manently encoded within the lock s fixed memory and when the lock is first started or...

Страница 43: ...of time PROGRAM CARDS Used with Program Card Programming operation two ordinary proximity cards are made into Program Cards permit ting all programming to be performed at the lock s Proximity Reader...

Страница 44: ...ducts In no event shall NAPCO be liable for an amount in ex cess of NAPCO s original selling price of the product for any loss or damage whether direct indirect incidental consequential or otherwise a...

Отзывы: