21
60. Number of Attempts Before Lockout
61. Set the Attempts Lockout Time
Number of attempts before lockout must be 1-9 attempts.
The number of attempts is reduced by half every time the keypad is locked out without a
successful code entry (default is 6 attempts).
The attempt count is reset each time a valid code is entered.
Lockout Time must be 1-60 seconds.
How long the keypad is locked-out after a series of unsuccessful attempts
(default is 18 seconds).
4
4
LOCKOUT
; 6 0 ;
[ _ ]
:
(Number of Attempts)
; 6 1 ;
[ _ _ ]
:
(Lockout Time)
62-63. Reserved
"Keypad Programming" Functions (cont'd)
56 - 59. Reserved
; 6 4 :
64. Disable Remote Input
Wire a Normally Open Contact to Wires (White & White). Momentarily close switch to unlock door
to allow person to pass through door.
Enter the functions below to Disable/Enable the Remote Input.
NOTE:
The Remote Input is enabled as part of the default program.
Remote Input / Wireless Remote Release Pairing
; 6 5 :
65. Enable Remote Input
2
REMOTE INPUT
; 6 5 ;
[ ____ ]
:
Slot Number
(1-10)
65. Pair Wireless Remote Release
Note:
In addition to using a wired momentary switch, Function 65 is
also used to pair a compatible Wireless Remote Release such as the
RR-
1BUTTON
(see WI1999) or the portable pocket-size
RR-4BKEYFOB
(see
WI2004). Function 64 is also used to remove all paired Wireless Remote
Releases from the locking device.
Be aware of the potential loss of Wireless
Remote Release pairing(s) that can result from using Function 64
. Refer to
the above WIs for complete instructions.
66. Reserved
55. Enable 30 Second Smart Pass
Smart Pass
Enabling this feature overrides the existing Pass Time and sets the duration to 30 sec-
onds. Therefore, after a valid credential has been presented, the ArchiTech series lock
will remain unlocked for 30 seconds OR until the door opens or closes.
Note:
The above
function is dependent upon the door position (a Door Contact Sensor is required).
4
SMART PASS
; 5 5 :