Страница 1: ...Header Installation Instructions with EML 310 320 and 371 372 For 4 1 8 4 1 2 6 Headers For use with DRS Rails and Patch Fittings Installation instructions 933903 07 2019 EN ...

Страница 2: ...in diameter specifications 7 2 RTS88 and PT21 installation instructions 8 2 1 Install header for single or double door RTS88 8 2 2 Install header for single or double door PT21 9 2 3 RTS88 adjustments 10 2 4 PT21 adjustments 10 3 EML and shim installation instructions 11 3 1 Prepare disassemble mag lock body and mounting plate 11 3 2 Secure header shim to frame ceiling surface for 4 1 8 or 4 1 2 h...

Страница 3: ...sses are optional but not required Clamping area must be flat and uncoated no self cleaning coating Never use glass with conchoidal fractures and or damaged edges 1 1 4 Safety instructions Installation requires two people Always wear protective clothing Only properly qualified and specially trained staff are authorized to mount dormakaba glass hardware Due to crushing hazards and possible injury c...

Страница 4: ...e by an experienced installer with knowledge of this product NOTE It is highly recommended that thread locking compound be applied to all screws during installation to reduce chance of screws loosening over extended time 1 1 2 Listings These products have been successfully tested and evaluated by UL in two separate categories for use in both the United States and Canada Auxiliary Lock The GWXT fir...

Страница 5: ... notice Power Supply Voltage EML310 EML320 EML371 EML372 12VDC 0 65A 0 65A x 2 1 30A 0 52A 0 52A x 2 1 04A 24VDC 0 45A 0 45A x 2 0 90A 0 26A 0 26A x 2 0 52A NOTE All dormakaba electromagnetic locks must be powered with a Listed filtered and regulated DC power supplies such as the dormakaba PS Series UL Listed Power Supply dormakaba offers a full line of power supplies and switching devices that ar...

Страница 6: ...d 371 372 For use with DRS Rails and Patching Fittings 4 1 8 4 1 2 6 Headers 933903 07 2019 EML Header Shim 6 EML header options 1 3 EML header options EML 310 320 for 4 1 8 and 4 1 2 Headers EML 371 372 for 4 1 8 and 4 1 2 Headers EML 371 372 for 6 Headers Fig 1 ...

Страница 7: ...s with EML310 320 and 371 372 For use with DRS Rails and Patching Fittings 4 1 8 4 1 2 6 Headers 933903 07 2019 EML Header Shim 7 Pin diameter 1 4 Pin diameter specifications Fig 2 Universal PT21 pivot pin MUNDUS PT21 pivot pin 5 8 15 9 16 14 ...

Страница 8: ...ount Figure 2B Secure header to overhead frame only using appropriate fasteners NOTE Always ensure the proper fasteners and adequate number of fixing points for your specific field conditions 2 1 3 Resecure RTS88 closer inside header tube using included fasteners 2 1 4 Adjust closer if necessary See adjustments section 2 3 2 1 5 Snap cover cap and flat cover back into place 2 1 6 For double door a...

Страница 9: ...ng appropriate fasteners dependent upon application NOTE Always ensure the proper fasteners and adequate number of fixing points for your specific field conditions 2 2 4 Adjust PT21 if necessary See adjustment section 2 4 2 2 5 Snap cover cap and flat cover back into place 2 2 6 For double door applications follow steps 2 1 1 through 2 1 4 NOTE IF NECESSARY ENSURE HOLES ARE CUT INTO HEADER FOR FEE...

Страница 10: ... Valve B Valve A Valve A Closing sweep speed from maximum opening to 0 Clockwise decrease closing speed Counter clockwise increase closing speed Valve B Latch speed from maximum opening to 20 Clockwise decrease closing speed Counter clockwise increase closing speed Slotted holes in angle bracket 2 4 PT21 adjustments 2 4 1 Ensure PT21 is plumb and level 2 4 2 Raise pivot pin up completely by rotati...

Страница 11: ...e locations 3 2 Secure header shim to frame ceiling surface for 4 1 8 or 4 1 2 headers only Fig 8 3 1 1 Remove anti tamper screws to access captive mounting screws 3 1 3 Slide and lift mounting bracket from mag lock body screws Anti tamper screws Access to captive mounting screws Captive mounting screws Mounting bracket Mag lock body screws Mounting bracket EML 371 372 header shim shown Header tub...

Страница 12: ...mag lock body screws into slots in mounting bracket 3 3 Secure mounting bracket and mag lock to shim for 4 1 8 or 4 1 2 headers only Fig 9 Mounting bracket Mounting bracket Shim Mag lock body 3 3 3 Slide mag lock body backward and into place in slots 3 3 4 Rethread captive mounting screws 3 3 5 Reinsert one 1 anti tamper screw NOTE Other anti tamper screw to reinsert later Access needed to wiring ...

Страница 13: ...priate fasteners Hex key size 4mm 3 4 2 Secure mag lock body to mounting bracket Insert mag lock body screws into slots in mounting bracket Mounting bracket Mounting bracket Shim Mag lock body 3 4 3 Slide mag lock body backward and into place in slots 3 4 4 Rethread captive mounting screws 3 4 5 Reinsert one 1 anti tamper screw NOTE Other anti tamper screw to reinsert later Access needed to wiring...

Страница 14: ...washer Mark bracket location Glass door bracket assem Set screws U shaped bracket cover Center mounting bolt Pin Armature plate A B C D E NOTE Armature plate should remain movable See step 4 1 9 on this page NOTE Armature plate must be allowed to pivot on the center mounting bolt to allow proper alignment with the magnet surface If not properly aligned with the magnet surface the lock may lose hol...

Страница 15: ...ould remain movable See step 4 2 3 on this page NOTE Armature plate must be allowed to pivot on the center mounting bolt to allow proper alignment with the magnet surface If not properly aligned with the magnet surface the lock may lose holding force or not lock at all NOTE The head of the armature mounting bolt ships with a rubber washer affixed to it Ensure this washer projects slightly beyond t...

Страница 16: ...etect a problem 5 3 Lock monitoring options DP Door Position Sensor NOTE Surfaces must be kept free of contaminating materials NOTE Lock surface and armature plate must be cleaned periodically with a non abrasive cleanser NOTE Armature plate and magnet must be properly aligned to ensure proper sensor function NOTE Lock status is indicated via LED mounted on bottom of lock housing Green LED door lo...

Страница 17: ...Table 1 Wire gauge selections load current at 24V Total one way length of wire run ft Load current 1 4A 1 2A 3 4A 1A 1 1 4A 1 1 2A 100 18 16 14 12 12 10 150 16 14 12 10 10 200 16 12 10 10 250 14 12 10 300 14 10 400 12 10 500 12 750 10 Table 2 Wire gauge selections load current at 12V Header tube NOTE Header tube hidden for easier viewing Shim Shim Mag lock body Mag lock body Wiring cavity cover Po...

Страница 18: ...relock mode each time power is applied even if J2 has been removed NORMALLY OPEN NORMALLY CLOSED COMMON COMMON GROUND 12 24VDC INPUT Optional BA Sensor SPDT Output contacts rated for max 1 25 Amp at 24 VDC Lock powered from a Listed filtered and regulated DC Power Supply RED NORMALLY CLOSED BLACK COMMON GREEN NORMALLY OPEN See Optional Delayed Relock Options Below DELAY RW1 MAG J2 LED 1 DELAY RELO...

Страница 19: ...Sensor SPDT Output contacts rated for maximum 1 00 Amperes at 24VDC Common Normally Open Normally Closed Fig 17 Power input requirements Model 12VDC 24VDC EML371 0 52A 0 26A EML372 1 04A 0 52A 12 24VDC input Ground Magnet power from Power Supply Jumper 12VDC Jumper 24VDC preset Optional DP contacts are rated 0 20A 12VDC and 0 12A at 24VDC 2 x BLUE LEADS Normally Open shown with Door Open Optional ...

Страница 20: ...ption Lock has enough holding force to lightly hold a screwdriver or set of pliers but door will not lock Check to see that armature plate is correctly aligned with the electromagnetic lock If there is improper alignment make a 1 4 turn of the armature plate mounting bolt and check for alignment Make sure to follow the armature plate mounting instructions Lock is operating and locking but the arma...

Страница 21: ...www dormakaba com dormakaba DORMA USA Inc 1 Dorma Drive Drawer AC Reamstown PA 17567 USA T 717 336 3881 F 717 336 2106 ...