24
"Keypad Programming" Function 67-68 (cont'd)
above, when feature 56 is enabled, and whenever the deadbolt extends, the ArchiTech lock will
always
change to a
"locked" state. Enabling feature 57 allows the user to press the "
Program / Passage
" button before exiting to allow the
ArchiTech lock to remain in an "unlocked" state, even when the door closes and the automatic deadbolt extends for
the first time; the external lever will remain mechanically connected to the deadbolt / latch to allow re-entry, and will
only re-lock upon either a subsequent retraction and extension of the deadbolt, or upon a valid credential. This feature
is best explained using the following step-by-step example:
Example:
A door is equipped with an automatic deadbolt and features 56 and 57 are enabled. The door is
closed, the ArchiTech lock is in a "locked" state and the deadbolt is extended. A user inside the protected premises
turns the inside lever, simultaneously causing the ArchiTech latch and deadbolt to retract. The user opens the door,
presses the "
Program / Passage
" button
*
, and exits the premises. When the door closes, the automatic deadbolt ex-
tends for the first time, and the ArchiTech lock remains in an "unlocked" state for the duration of this first deadbolt ex-
tension. At this point, the user may re-enter the premises by simply turning the outside handle (thus simultaneously
retracting both the deadbolt and latch). If the user does re-enter the premises, upon door closure the automatic dead-
bolt will extend for the second time and the ArchiTech lock will go into a "locked" state. Presumably the user will be
inside the premises, but does not need to be; if the user chooses to remain outside the premises during the second
deadbolt extension, a valid credential will be required to allow entry.
IMPORTANT:
The user MUST press the
Pro-
gram / Passage
button to activate this
Enable One-Time Entry Option
; if the button is not pressed, the lock
will relock when the door closes.
58.
Enable Toggle Mode (Manual Relock).
The intent of this feature is to prevent user lockout by always toggling
either permanent "locked" or permanent "unlocked". When the current state of the lock is "locked" and this feature is
enabled, either a valid credential or the turning of the inside handle will always cause the lock to remain in Passage
("unlocked") permanently. The lock may subsequently be locked ("Passage disabled") by either a valid credential or
by pressing the "
Program / Passage
" button on the Networx Control Unit. Compatible models only. See feature 36,
"
Cancel Passage on Button Press
".
*
or presses the Remote Release button (must be configured independently for Remote Release / Toggle Mode).
;
6
7
;
[ _ _ ]
:
(Feature
Number)
67. Program System Features (cont'd)
67.
Set All Function 67 Features to OFF
This special Function 67 command will set all system features to "OFF" (disabled), regardless of their individual default settings.
This Function exists because some Function 67 features are "ON" by default, and cannot be toggled "OFF"; the only way to
turn them off is to use this Function. Compare this to Function 68.
4
;
67
;
0
0
0
:
Disable All System Features
Function 68 will "clear" all Function 67 system features by setting them all to their factory
default
states.
4
Clear (Default) All System Features
68. Default All System Features
;
68
;
0
0
0
: