28
"DL-Windows Mode" Operation / Features
This section highlights the considerations when using the ArchiTech series lock in a mode integrated with the DL-
Windows software (version 5.2 and up). When using the lock in "DL-Windows Mode" (also called "Networx Mode"),
credentials and lock features can be sent to the lock wirelessly using a Networx Gateway. For different types of Gate-
way modules, see page 4.
Note:
After lock has been configured (added) to the Networx Gateway, it will remain un-
locked until a valid credential is presented to the Proximity Reader.
IMPORTANT:
All proximity credentials manually added in " Program Card Programming"
will be deleted
upon
the locks' enrollment into the DL-Windows Networx system.
If you are new to DL-Windows and Networx, stop here and read the
DL-Windows User Guide
(OI382) for a basic over-
view of DL-Windows. Many of the terms detailed in this manual are explained in OI382 and also the
DL-Windows for
Networx User Guide
(OI383).
Lock Types
The ArchiTech series locks are available in various design combinations, therefore the "
Lock
Types
" in DL-Windows must be carefully selected. Use the control unit label (example shown
at right) to make the proper selections in the DL-Windows
New Lock Profile
screen.
Note:
An
identical label is located on the provided yellow Lock ID card.
An example "
N95I2
"
Lock Type
selection is shown below:
Note:
Correct " Lock Types" are required for successful-
ly linking a physical lock to the DL-Windows "Lock Pro-
file" (see "
What is a Lock Program?
" on page 5 for further
information).
Temporary Credentials
Proximity credentials added during "Program Card Program-
ming" are deleted upon enrollment into the DL-Windows Net-
worx system. Even after Networx enrollment and integration,
proximity credentials may still be manually added, just like in
"Program Card Programming". However, upon sending a
Lock Profile from DL-Windows to the lock,
all manually added
cards and other credentials will be overwritten and/or delet-
ed, with the exception of User Numbers 6000 and 6001
.
Though not recommended, if proximity credentials are manu-
ally added in "DL-Windows Mode", they will be added to the
next available slot. For example, if you already added cre-
dentials to slots 12-16, the manually added credential will be
written into slot 17.
"Program Card" Considerations
If "Program Cards" were created / enrolled ("Program Card Programming") prior to integration with DL-Windows,
the "Program Cards" will NOT be overwritten and will remain in the lock memory.
"Program Cards" are added to User Numbers ("slots") 6000 and 6001, and are logged accordingly.
"Program Cards" have the same functionality as Administrative Users (credentials added to any of the slots num-
bered 2 through 11 in DL-Windows). See the "
ArchiTech User Number Definitions
" chart on page 7.