NAPCO Security Systems
LIBRA LIB-P432EX Series Programming Instructions
Page 21
KEYPAD ADDRESS PROGRAM MODE DISPLAY
DIRECT ADDRESS PROGRAM MODE KEYPAD COMMANDS
A. GEM-DXK2 (and GEM-DXRP2) Keypad
GEM-DXRP2 / GEM-DXK2 Keypads
00003C
1
2
= ADDRESS LOCATION
1
2
= DATA ENTRY LOCATION (Left and Right Digits)
Press
w
followed by (1) the 4 digit
address location, and (2) the corresponding
data shown.
(Direct Entry)
3
P
INTERIOR BYPASS
FIRE/TBL SYS TBL
CHIME
3C
INTERIOR BYPASS
SYS TBL
CHIME
FIRE/TBL
1
2
Flashing
GEM-DXRP3 / GEM-DXK3 Keypads
Press
w
followed by (1) the 4 digit
address location, and (2) the corresponding
data shown.
Note:
A long beep sounds
when in Address Program Mode.
1
2
GEM-DXK4RF Series Keypads
P
3C
0 0 0 0 3 C
To access, press
y
in
Dealer Program Mode.
1. Toggle Cursor to 4-digit ad-
dress field using the
w
button.
2. Enter address Number directly
using number buttons (0-9).
3. Enter Data directly using num-
ber buttons.*
4. Press the
u
button to save.
To exit, press
y
.
NOTE:
Press
0
button to clear character at cursor.
Select NEXT/PRIOR Address.
Press
Gp
to jump to next programming block.
*
Press
G0
through
G5
for 10-15, respectively.
GEM-DXK2
Содержание LIBRA LIB-P432EX
Страница 64: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 64 LIB P432EX WIRING DIAGRAM...
Страница 65: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 65 LIB P432EXT WIRING DIAGRAM...
Страница 66: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 66 LIB P432EXT 230 WIRING DIAGRAM...
Страница 67: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 67 NOTES...