LIBRA LIB-P432EX Series Programming Instructions
NAPCO Security Systems
Page 18
Key Fob Transmitters
(Press
w
to set cursor).
Keyfobs can be programmed as "Arm/Disarm" devices (refer to WI752).
For each Key Fob Transmitter, enter:
The Key Fob Transmitter number (01–08).
Area number to which transmitter is assigned (1 - 4); enter 0 to disable keyfob.
The 6-digit RF ID # printed on the transmitter (enter all numbers and/or letters, including
leading "0"s, if any).
1-digit checksum number printed on the transmitter (enter all numbers and/or letters, including leading "0"s, if any).
Aux-1 Option (see key fob aux 1 & aux 2 options).
Aux-2 Option (see key fob aux 1 & aux 2 options).
Press
u
to save. Press NEXT ("
r
" or
p
) to proceed.
Note:
If the Key Fob is converted for Two Button "Emergency Use" (by cutting an internal
jumper), both top or bottom buttons must be depressed to activate an alarm. In this case, the
Aux-1 and Aux-2 cannot be programmed.
Key Fob Transmitters as Zone Input Devices
(refer to display above: press
PRIOR ("
X
" or
q
)
to go backwards).
Each of the 4 key fob buttons can be assigned to a zone. For example, On button = point 1; Off
button = point 2; A1 = point 3; A2 = point 4. Up to 64 key fobs (using 1 button) or 32 key fobs
(using 2 buttons) or 16 key fobs (using all 4 buttons) or any combination up to a maximum of 64
controlled zones can be assigned, providing multiple wireless panic buttons on a system, each reporting to the Central Station or a
pager and/or annunciating on a keypad the key fob zone number with description/location.
To assign a key fob to a zone:
program the key fob as you would a transmitter, entering the key fob's ID code, check sum and point number at the appropriate
zone. The "Quick Method" is not allowed. The zone may be hardwired to a sensor as well as assigned to a key fob (either one
will activate the zone alarm output).
NOTE:
If assigning a key fob to a zone, the "ON/OFF" buttons on the key fob will no longer
arm/disarm the system. The key fob is converted to a "panic only" device.
NOTE: Key fobs 1-8 report openings and
closings as Users 57-64.
DATA
ENTRY
AUX 1/AUX 2
OPTIONS
0
None
1
Relay Group 1 Toggle
2
Relay Group 2 Toggle
9
Panic
A
Auxiliary
B
Instant
C
PGM2 Output Toggle
D
Access on PGM2
Output
E
Arm Stay
F
Interior Button
29
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
KEY FOB ZONE ASSIGNMENT:
Key fobs can also be assigned to zones to allow multiple wireless panic buttons on
one alarm system, each reporting to a central station, a pager or having a description on the keypad that describes the
person holding the key fob, the location where the person holding the key fob is stationed, or the special purpose of the
key fob button being depressed.
See the next page on key fob Zone Assignment.
Содержание LIBRA LIB-P432EX
Страница 64: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 64 LIB P432EX WIRING DIAGRAM...
Страница 65: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 65 LIB P432EXT WIRING DIAGRAM...
Страница 66: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 66 LIB P432EXT 230 WIRING DIAGRAM...
Страница 67: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 67 NOTES...