LIBRA LIB-P432EX Series Programming Instructions
NAPCO Security Systems
Page 24
SYSTEM DELAYS & TIMEOUTS (ADDRESS 0000-0002, 1413, 1417, 2050 & 2055)
1. Select delay/timeout (0-255 sec.) from the table shown.
2. Enter in corresponding address locations above (left and right digits).
3. For a desired delay/timeout not listed do the following:
A. Choose a desired delay/timeout, ex: 20 sec.
B. Divide it by 16
4. Press
U
or
D
to save.
EXIT/ENTRY DELAYS:
Apply only to zones programmed with the following options “Exit/
Entry 1, Exit/Entry 2, Exit/Entry Follower”.
NOTE:
Sensor Watch Time Options are similar
to above table, except in hours.
1 Quotient Left Digit
16 20
16
4 Remainder Right Digit
SYSTEM DELAYS & TIMEOUTS (ADDRESS 1418 & 1419)
DEFAULTS:
The defaults shown on this
page and on the following pages are
automatically set after exiting the Easy
Menu Driven Mode.
1. Select delay/timeout from the table shown.
2. Enter in corresponding address locations above (left and right digits).
3. For a desired delay/timeout not listed do the following:
A. Choose a desired delay/timeout, ex: 20
B. Divide it by 16
4. Press
u
to save.
1 Quotient Left Digit
16 20
16
4 Remainder Right Digit
PROGRAMMING STEPS:
1. Lookup desired Programming Option by
Address Location (highlighted in black).
2. Select the programming option data entry
from the tables shown.
3. Enter the selected data entry in the boxes
shown.
4. For more information on a programming
option refer to the Glossary at the end of
this manual.
EXIT
ADDRESS 0000
DELAY
LEFT RIGHT
(sec.)
[Default = 3 C]
ENTRY
ADDRESS 0001
DELAY 1
LEFT RIGHT
(sec.)
[Default = 1 E]
ENTRY
ADDRESS 0002
DELAY 2
LEFT RIGHT
(sec.)
[Default = 1 E]
PGM2 Output
ADDRESS 1413
Access Cntrl
LEFT RIGHT
Timeout (sec.)
[Default = blank (•) blank (•)]
ABORT
ADDRESS 1417
DELAY
LEFT RIGHT
(sec.)
[Default = 1 E]
Sensor Watch
ADDRESS 2050
Time
LEFT RIGHT
(Hrs.)
[Default = 24 HRS = 1 8
Report Cancel
ADDRESS 2055
Window
LEFT RIGHT
(min.)
[Default = zero minutes =
blank (•) blank (•)]
AC Fail
ADDRESS 1419
Report Delay
LEFT RIGHT
(min.)
[Default = 60 mins. = 3 C]
CHIME
ADDRESS 1418
TIME
LEFT RIGHT
(¼sec.)
[Default = 2 sec. = blank (•) 8]
ADDRESS LOC.
Program
LEFT RIGHT
Option
ENTER DATA
CHIME TIMEOUT OPTIONS
TIMEOUT
LEFT
RIGHT
blank (•) blank (•)
(0) ¼sec. = 0 sec.
blank (•)
2
(2) ¼sec. = ½ sec.
blank (•)
3
(3) ¼sec. = ¾ sec.
blank (•)
4
(4) ¼sec. = 1 sec.
blank (•)
5
(5) ¼sec. = 1.25 sec.
blank (•)
6
(6) ¼sec. = 1.5 sec.
blank (•)
7
(7) ¼sec. = 1.75 sec.
blank (•)
8
(8) ¼sec. = 2 sec.
F
F
(255) ¼sec. = 63.25
DATA ENTRIES
AC FAIL REPORT DELAY OPTIONS
TIMEOUT
LEFT
RIGHT
blank (•) blank (•)
blank (•)
blank (•)
1
1
blank (•)
2
2
blank (•)
3
3
blank (•)
4
4
blank (•)
5
5
blank (•)
6
6
blank (•)
7
7
F
F
255 min. = 4 Hr., 30 min.
DATA ENTRIES
DELAY/
LEFT
RIGHT TIMEOUT
blank (•) blank (•)
0 sec.
blank (•)
F
15 sec.
1
E
30 sec.
2
D
45 sec.
3
C
60 sec.
5
0
90 sec.
7
8
120 sec.
F
F
255 min.
DATA ENTRIES
PROGRAMMING TIMEOUTS:
Either use the tables provided or calculate your own timeout
using the steps indicated. WARNING:
Timers have uncertainty of +/-1sec, so a "time" of 1
second may actually timeout IMMEDIATELY.
Содержание LIBRA LIB-P432EX
Страница 64: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 64 LIB P432EX WIRING DIAGRAM...
Страница 65: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 65 LIB P432EXT WIRING DIAGRAM...
Страница 66: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 66 LIB P432EXT 230 WIRING DIAGRAM...
Страница 67: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 67 NOTES...