NAPCO Security Systems
LIBRA LIB-P432EX Series Programming Instructions
Page 11
Key Fob Transmitters as Arm/Disarm & Control Devices
(Press
w
to set cursor).
Keyfobs can be programmed as "Arm/Disarm" devices using their On/Off buttons (refer to WI752). For
each Key Fob Transmitter, enter:
The
Key Fob Transmitter number
(01–08). Press
01
through
08
for 01-08.
Area number
to which transmitter is assigned (0 to disable keyfob, 1 - 4). Press
0
,
1
and
2
for 0, 1 and 2, respectively.
The
6-digit RF ID #
printed on the transmitter (enter all numbers and/or letters, including leading "0"s,
if any): "0" through "9" =
0
through
9
; "A" =
G0
; "B" =
G1
; "C" =
G2
;
"D" =
G3
; "E" =
G4
and "F" =
G5
.
1-digit checksum number printed on the transmitter.
Aux 1 Option
(see key fob aux 1 & aux 2 options).
Aux 2 Option
(see key fob aux 1 & aux 2 options).
For Aux 1/Aux 2 Options: "0", "1", "2" and "9" =
0
,
1
,
2
and
9
, respectively; "A" =
G0
; "B" =
G1
; "C" =
G2
and "D" =
G3
.
If the Key Fob is converted for Two Button "Emergency Use" (by cutting an internal jumper), both top
or bottom buttons must be depressed to activate an alarm. In this case, the Aux-1 and Aux-2
cannot be programmed. Press
u
to save. Press NEXT ("
r
" or
p
) to proceed.
Key Fob Transmitters as Zone Input Devices
(refer to display as shown above: press the PRIOR/NO button to go backwards).
Each of the 4 key fob buttons can be assigned to a zone. For example, On button = point 1; Off button = point 2; A1 = point 3; A2 =
point 4. Up to 64 key fobs (using 1 button) or 32 key fobs (using 2 buttons) or 16 key fobs (using all 4 buttons) or any combination up
to a maximum of 64 controlled zones can be assigned, providing multiple wireless panic buttons on a system, each reporting to a
Central Station or a pager and/or annunciating on a keypad the key fob zone number with description/location.
To assign a key fob to
a zone:
program the keyfob as you would a transmitter, entering the keyfob's ID code, check sum and point number at the appropriate
zone. The "Quick Method" is not allowed. The zone may be hardwired to an electrical sensor as well as assigned to a key fob (either
one will activate the zone alarm output).
NOTE:
If assigning a key fob to a zone, the "ON/OFF" buttons on the key fob will no longer
arm/disarm the system. The key fob is converted to a "panic only" device.
Dealer Code
Directly enter the Dealer Code (default = 456789), including leading zeros. Use the
1
through
9
buttons.
NOTE:
Press
0
for a zero. Press
u
to save. Re-enter the Dealer Code to verify the
previous code. Press
u
to save. Press NEXT ("
r
" or
p
) to proceed.
ZONE DESCRIPTIONS:
GEM-DXRP2 cannot be used to enter
Zone Descriptions. To enter Zone Descriptions, you must use the
GEM-DXRP1 Keypad / GEM-DXK1 Keypad (See WI1690) or the Napco PCD-Windows Quickloader Software.
DATA
ENTRY
AUX 1/AUX 2
OPTIONS
0
None
1
Relay Group 1 Toggle
2
Relay Group 2 Toggle
9
Keypad Panic
A
Keypad Aux.
B
Instant
C
PGM2 Ouput Toggle
D
Access on PGM2 Output
E
Arm Stay
F
Interior Button
(Direct Entry)
K F o b 0 1
A r e a
(Direct Entry)
0 0 0 0 0 0
(Direct Entry)
: 0 0 0
(Direct Entry)
R E - E N T
(Direct Entry)
4 5 6 7 8 9
(Direct Entry)
D C o d e
KEY FOB ZONE ASSIGNMENT:
Key fobs can also be assigned to zones to allow multiple wireless panic buttons on one alarm
system, each reporting to a central station, a pager or having a description on the keypad that describes the person holding the key
fob, the location where the person holding the key fob is stationed, or the special purpose of the key fob button being depressed.
See Key Fob Transmitters as Zone Input Devices .
Содержание LIBRA LIB-P432EX
Страница 64: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 64 LIB P432EX WIRING DIAGRAM...
Страница 65: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 65 LIB P432EXT WIRING DIAGRAM...
Страница 66: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 66 LIB P432EXT 230 WIRING DIAGRAM...
Страница 67: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 67 NOTES...