THIS MANUAL INCLUDES FEATURES WHICH ARE ONLY AVAILABLE IN
CONTROL PANEL FIRMWARE VERSION 30K OR LATER.
NAPCO Security Systems, Inc.
333 Bayview Avenue, Amityville, New York 11701
For Sales and Repairs, call toll free: (800) 645-9445
For direct line to Technical Service, call toll free: (800) 645-9440
Internet: http://www.napcosecurity.com
IMPORTANT NOTE
This manual supports the keypad programming of the LIB-P432EX series control panels with the NAPCO
GEM-
DXRP2
,
GEM-DXRP3
,
GEM-DXK2
,
GEM-DXK3
and
GEM-DXK4RF
Series Keypads. Compared with the "DXRP"
models, the "DXK Series" models offer simplified functionality with STAY (
p
) and AWAY (
q
) buttons, and a
different icon printed on the ENTER (
u
) button.
While the programming instructions in this manual are depicted using the "DXK Series" models, this manual also ap-
plies to the "DXRP" models because keypad
Program Mode
is identical for both types of keypads--
only the button
icons are different
, as follows:
•
The
v
button and the
u
button operate identically (in Program Mode) for both keypads.
•
The "Interior" (
p
) button and the "STAY" (
p
) button operate identically (in Program Mode) for both key-
pads. These buttons are also used to answer "
YES
" or "
NEXT
" to questions that appear on the keypad display;
on occasion, a checkmark "
r
" or a down arrow "
ª
" may be used in this manual as well.
•
The "Instant" (
z
) button and the "AWAY" (
q
) button operate identically (in Program Mode) for both key-
pads. These buttons are also used to answer "
NO
" or "
PRIOR
" to questions that appear on the keypad display;
on occasion, an "
X
" symbol or an up arrow "
©
" may be used as well.
For consistency, it is recommended that all keypads used in one alarm system either be all type "DXRP" or all
"DXK Series" -- both keypad types should not be used in one alarm system.
The following applies to the LIB-P432EXT and LIB-P432EXT-230 control panels only:
Telephone Connection
The
LIB-P432EXT and LIB-P432EXT-230
products under the R&TTE Directive 99/5/EC complies with the CTR21 regulation and may be used on the
PUBLIC network with the following restrictions:
•
Do NOT use the ROTARY Dialing feature as this is not evaluated in CTR21.
Special Programming
•
Pulse dialing is NOT to be used. Programming location
0788 CS SYSTEM REPORT OPTIONS
shall have the right digit entry always a 2 (=
Touch-Tone Dialing only). If using the option of "Disable Dial Tone Detect" in location 0788 then a 3 second pause must precede the "CS re-
ceiver telephone number" by entering a D before the telephone number.
•
Note:
Address 1424, "Disable Code Required for EZ Bypass", the default panel configuration is "OFF".
WARNING: If using the EZ Driven Program Mode, be aware that all EN501 defaults will be deleted.
Refer to page 56 of the Installation Instructions (WI1691) for setting the EN50131-1 features.
Содержание LIBRA LIB-P432EX
Страница 64: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 64 LIB P432EX WIRING DIAGRAM...
Страница 65: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 65 LIB P432EXT WIRING DIAGRAM...
Страница 66: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 66 LIB P432EXT 230 WIRING DIAGRAM...
Страница 67: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 67 NOTES...