LIBRA LIB-P432EX Series Programming Instructions
NAPCO Security Systems
Page 52
RF RECEIVER & SUPERVISORY TIMER OPTIONS (ADDRESS 2029-2044 & 2056)
RF RECEIVERS:
Up to 2 RF Receivers may be programmed.
1. Select the number of receivers from the table shown.
2. Enter in corresponding right digit address location shown
(left digit is not used).
3. Press
u
to save.
RF SUPERVISORY TIMERS:
RF Supervisory Timers may be programmed for each type of
transmitter used. A transmitter will send a transmission every time it is tripped, when there is NO
activity, the transmitter sends a status transmission about once an hour. If the receiver does NOT
receive ANY signal (a trip or a status) from a transmitter in the time specified for transmitter type, a
system trouble “
WIRELESS TROUBLE/E04-NN SERVICE
” will be displayed at the keypad.
1. Select timer delay from the table shown. Timers are programmed in increments of 30 minutes
each. Valid entries are [blank (•)3]-[blank (•)F], 90 minutes-450 minutes.
2. Enter in corresponding address locations above right digit only (left digit is not used).
3. Press
u
to save.
NOTE:
These timers apply only to Supervised RF Transmitters (see RF Transmitters in Easy
Menu Driven Mode Programming).
[Default = blank (•) blank (•) from address 2029-2044]
RF SUPERVISORY
TIMER
RF TRANSMITTER
LEFT
ADDR
RIGHT
Type 0
Window/Door, 2 Pt.
blank (•)
2029
Type 1
Window/Door, 2 Pt.
blank (•)
2030
Type 2
Window/Door, 2 Pt.
blank (•)
2031
Type 3
Window/Door, 2 Pt.
blank (•)
2032
Type 4
RESERVED
blank (•)
2033
Type 5
PIR
blank (•)
2034
Type 6
PIR
blank (•)
2035
Type 7
Smoke Detector
blank (•)
2036
ADDRESS
2029-2036
RF SUPERVISORY
TIMER
RF TRANSMITTER
LEFT
ADDR
RIGHT
Type 8
Smoke Detector
blank (•)
2037
Type 9
RESERVED
blank (•)
2038
Type A
Dual Tech.
blank (•)
2039
Type B
RESERVED
blank (•)
2040
Type C
Window/Door, 4 Pt.
blank (•)
2041
Type D
PIR
blank (•)
2042
Type E
Smoke Detector
blank (•)
2043
Type F
Napco Glass Break
blank (•)
2044
ADDRESS
2037-2044
RF SUPERVISORY TIMERS
DELAY
LEFT
RIGHT
blank (•)
3
90 min.
blank (•)
4
120 min.
blank (•)
5
150 min.
blank (•)
6
180 min.
blank (•)
7
210 min.
blank (•)
8
240 min.
blank (•)
9
270 min.
blank (•)
0
300 min.
blank (•)
B
330 min.
blank (•)
C
360 min.
blank (•)
D
390 min.
blank (•)
E
420 min.
blank (•)
F
450 min.
DATA ENTRIES
DATA
ENTRIES
RF Receiver(s)
RIGHT
blank (•)
None
1
1
2
2
Default for Number of Receivers
depends on Easy Menu Question for
RF Transmitters.
Number of RF
LEFT
RIGHT
Receivers
blank (•)
ADDRESS 2056
Содержание LIBRA LIB-P432EX
Страница 64: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 64 LIB P432EX WIRING DIAGRAM...
Страница 65: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 65 LIB P432EXT WIRING DIAGRAM...
Страница 66: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 66 LIB P432EXT 230 WIRING DIAGRAM...
Страница 67: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 67 NOTES...