NAPCO Security Systems
LIBRA LIB-P432EX Series Programming Instructions
Page 25
SYSTEM OUTPUT TIMEOUTS (ADDRESS 1412 & 1414-1416)
1. Select delay/timeout (0-255 min.) from the table shown.
2. Enter in corresponding address locations above (left and right digits).
3. For a desired delay/timeout not listed do the following:
A. Choose a desired delay/timeout, ex: 20 min.
B. Divide it by 16
4. Press
u
to save.
OUTPUT TIMEOUTS:
If a timeout of “0 min.” is selected, then the output will remain active (ON)
until the system is reset or disarmed.
1 Quotient Left Digit
16 20
16
4 Remainder Right Digit
DOWNLOAD/CALLBACK OPTIONS (ADDRESS 2059 & 0526-0545)
NUMBER OF RINGS BEFORE PICKUP:
Enter the number of rings before automatic pickup by the control
panel when downloading from a computer (see installation instructions WI1691 for more information).
1. Enter in right digit only (left digit is not used).
2. Valid entries are: 3-9, 0 = 10, B = 11, C = 12, D = 13, E = 14, F = 15
NOTE:
Default is 15 Rings. Dark shaded data shows option not available.
3. Press
u
to save.
CALLBACK TELEPHONE NUMBER:
Enter telephone number to be used when downloading from a computer (see installation in-
structions WI1691 for more information).
1. Enter in right digit only (left digit is not used).
2. Enter up to 20 digits from left to right.
NOTE:
Leave trailing boxes blank (•). For a zero, press
G0
.
3. Valid entries are: 1-9, B =
*
button, C =
#
button, D = 3 sec. pause, E = Wait for dial tone, F = ignore location.
4. Press
u
to save.
PAGER FORMAT OPTIONS (ADDRESS 0546 & 0547)
LEADING DIGITS FOR PAGER FORMAT:
In Pager Format reporting, the message typically begins with “00”.
However, for some pager services, this will cause the Pager's Voice Mail feature to activate.
This option allows you
to program these digits to any number desired. A typical Pager report is “003 22 1234”, where 3 is the Event, 22 is
the zone, and 1234 is the Subscriber ID number. For example, if the Leading Digits are programmed as “98”, the
Pager report will now appear as “983 22 1234”.
NOTE:
See CS Receiver Options to select Pager Format.
1. Enter in 1st and 2nd Leading Digits in right digit only (left digit is not used) as shown.
2. Valid entries are: 0-9.
3. Press
u
to save.
CALLBACK
ADDRESS 0526-0545 (RIGHT DIGITS 1-20)
Telephone
0526 0527 0528 0529 0530 0531 0532 0533 0534 0535 0536 0537 0538 0539 0540 0541 0542 0543 0544 0545
Number
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
(Digits 1-20)
[Default = blank (•) for all digits 1-20]
No. Rings
ADDRESS 2059
Before
LEFT RIGHT
Pickup
blank (•)
[Default = blank (•) blank (•)]
PGM2
ADDRESS 1412
Output
LEFT RIGHT
Timeout (min.)
[Default = blank (•) blank (•)]
Alarm
ADDRESS 1414
Output
LEFT RIGHT
Timeout (min.)
[Default = 15 mins. = (blank) F]
Pulse Alarm
ADDRESS 1415
Output
LEFT RIGHT
Timeout (min.)
[Default = 15 mins. = (blank) F]
PGM1
ADDRESS 1416
Output
LEFT RIGHT
Timeout (min.)
[Default = blank (•) blank (•)]
DATA ENTRIES DELAY/
LEFT
RIGHT TIMEOUT
blank (•) blank (•)
0 min.
blank (•)
1
1 min.
blank (•)
2
2 min.
blank (•)
3
3 min.
blank (•)
4
4 min.
blank (•)
5
5 min.
blank (•)
6
6 min.
1
blank (•) 16 min.
F
F
255 min.
Leading Digits for
Pager Format
LEFT RIGHT
(1st Digit)
blank (•)
ADDRESS 0546
Leading Digits for
ADDRESS 0547
Pager Format
LEFT RIGHT
(2nd Digit)
blank (•)
[Default = blank (•) blank (•)]
Содержание LIBRA LIB-P432EX
Страница 64: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 64 LIB P432EX WIRING DIAGRAM...
Страница 65: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 65 LIB P432EXT WIRING DIAGRAM...
Страница 66: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 66 LIB P432EXT 230 WIRING DIAGRAM...
Страница 67: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 67 NOTES...