FP
Σ
Specifications
13 - 12
13.3 Relays, Memory Areas and Constants
Item
Number of points and
range of memory area avail-
able for use
Function
FPG-C32T
FPG-C24R2
FPG-C32T2
Relay
External input relay
(
*
Note 1)
(X)
512 points
(X0 to X31F)
1,184 points
(X0 to X73F)
Turn on or off based on external input.
External output
relay (
*
Note 1)
(Y)
512 points
(Y0 to Y31F)
1,184 points
(Y0 to Y73F)
Externally outputs on or off state.
Internal relay
(
*
Note 2)
(R)
1,568 points (R0 to R97F)
Relay which turns on or off only within
program.
Link relay
(
*
Note 2)
(L)
1,024 points (L0 to L63F)
This relay is a shared relay used for
PLC link.
Timer (
*
Note 2)
(T)
1,024 points
(T0 to T1007/C1008 to C1023)
(
*
Note 3)
This goes on when the timer reaches
the specified time.
It corresponds to the timer number.
Counter (
*
Note 2)
(C)
This goes on when the timer
increments.
It corresponds to the timer number.
Special internal
relay
(R)
176 points (R9000 to R910F)
Relay which turns on or off based on
specific conditions and is used as a
flag.
Memory
area
External input relay
(
*
Note 1)
(WX)
32 words
(WX0 to WX31)
74 words
(WX0 to WX73)
Code for specifying 16 external input
points as one word (16 bits) of data.
External output
relay (
*
Note 1)
(WY)
32 words
(WY0 to WY31)
74 words
(WY0 to WY73)
Code for specifying 16 external output
points as one word (16 bits) of data.
Internal relay
(
*
Note 2)
(WR)
98 words (WR0 to WR97)
Code for specifying 16 internal relay
points as one word (16 bits) of data.
Link relay
(WL)
64 words (WL0 to WL63)
Code for specifying 16 link relay points
as one word (16 bits) of data.
Data register
(
*
Note 2)
(DT)
32,765 words (DT0 to DT32764)
Data memory used in program. Data is
handled in 16-bit units (one word).
Link data register
(
*
Note 2)
(LD)
128 words (LD0 to LD127)
This is a shared data memory which is
used within the PLC link. Data is han-
dled in 16-bit units (one word).
Timer/Counter set
value area
(
*
Note 2)
(SV)
1,024 words (SV0 to SV1023)
Data memory for storing a target value
of a timer and an initial value of a count-
er. Stores by timer/counter number.
Timer/Counter set
value area
(
*
Note 2)
(EV)
1,024 words (EV0 to EV1023)
Data memory for storing the elapsed
value during operation of a timer/count-
er. Stores by timer/ counter number.
Special data
register
(DT)
260 words (DT90000 to DT90259) Data memory for storing specific data.
Various settings and error codes are
stored.
Index register
(I)
14 words (I0 to ID)
Register can be used as an address of
memory area and constants modifier.
Содержание FP Series
Страница 15: ...FP Functions and Restrictions of the Unit 1 2...
Страница 25: ...FP Specifications and Functions of Control Unit 2 2...
Страница 37: ...FP Expansion 3 2...
Страница 44: ...Chapter 4 I O Allocation 4 1 I O Allocation 4 3...
Страница 45: ...FP I O Allocation 4 2...
Страница 51: ...FP Installation and Wiring 5 2...
Страница 77: ...FP High speed Counter and Pulse Output Functions 6 2...
Страница 133: ...FP High speed Counter and Pulse Output Functions 6 58...
Страница 135: ...FP Communication Cassette 7 2...
Страница 147: ...FP Communication Function 1 Computer Link 8 2...
Страница 169: ...FP Communication Function 2 General purpose Serial Communication 9 2...
Страница 205: ...FP Communication Function 2 General purpose Serial Communication 9 38...
Страница 207: ...FP Communication Function 3 PLC Link Function 10 2...
Страница 232: ...Chapter 11 Other Functions 11 1 Analog Potentiometer 11 3 11 2 Clock Calendar Function 11 4...
Страница 233: ...FP Other Functions 11 2...
Страница 238: ...Chapter 12 Self Diagnostic and Troubleshooting 12 1 Self Diagnostic Function 12 3 12 2 Troubleshooting 12 5...
Страница 239: ...FP Self Diagnostic and Troubleshooting 12 2...
Страница 249: ...FP Self Diagnostic and Troubleshooting 12 12...
Страница 251: ...FP Specifications 13 2...
Страница 323: ...Index FP I 4...
Страница 325: ...FP Record of changes R 2...