FP
Σ
Specifications
13 - 58
No.
Name
Boolean Operand Description
Steps
Special instructions
F138 Hours, minutes
and seconds
data to seconds
data
HMSS
S, D
Converts the hour, minute and second data of (S+1, S)
to seconds data, and the converted data is stored in
(D+1, D).
5
F139 Seconds data to
hours, minutes
and seconds
data
SHMS
S, D
Converts the seconds data of (S+1, S) to hour, minute
and second data, and the converted data is stored in
(D+1, D).
5
F140 Carry flag set
STC
Turns on the carry flag (R9009).
1
F141 Carry flag reset CLC
Turns off the carry flag (R9009).
1
F143 Partial I/O
update
IORF
D1, D2
Updates the I/O from the number specified by “D1” to
the number specified by “D2”.
Only possible for I/O numbers in a range of X0 to XF
and Y0 to YF.
5
F147 Printout
PR
S, D
Converts the ASCII code data in the area starting with
“S” for printing, and outputs it to the word external out-
put relay WY specified by “D”.
5
F148 Self-diagnostic
error set
ERR
n
(n: K100
to K299)
Stores the self-diagnostic error number “n” in DT90000
turns R9000 on, and turns on the ERROR/ALARM LED.
3
F149 Message
display
MSG
S
Displays the character constant of “S” in the connected
programming tool.
13
F157 Time addition
CADD
S1, S2, D
The time after (S2+1, S2) elapses from the time of
(S1+2, S1+1, S1) is stored in (D+2, D+1, D).
9
F158 Time
substruction
CSUB
S1, S2, D
The time that results from subtracting (S2+1, S2) from
the time (S1+2, S1+1, S1) is stored in (D+2, D+1, D).
9
F159 Serial data
communication
MTRN
S, n, D
This is used to send data to or receive data from an
external device through the specified COM., RS232C
or RS485 port.
7
BIN arithmetic instruction
F160 Double word
(32-bit) data
square root
DSQR
S, D
√
(S)
→
(D)
7
High-speed counter and pulse output control instructions
F0
High-speed
counter and
pulse output
control
MV
S,
DT90052
Performs high-speed counter control according to the
control code specified by “S”.
5
F1
Change and
read of the
elapsed value
DMV
S,
DT90044
Transfers (S+1, S) to high-speed counter elapsed val-
ue area (DT90045, DT90044). (
*
Note)
7
elapsed value
of high-speed
counter
DT90044,
D
Transfers value in high-speed counter elapsed value
area (DT90045, DT90044) to (D+1, D). (
*
Note)
7
Note
The elapsed value area varies depending on the channel being
used.
Содержание FP Series
Страница 15: ...FP Functions and Restrictions of the Unit 1 2...
Страница 25: ...FP Specifications and Functions of Control Unit 2 2...
Страница 37: ...FP Expansion 3 2...
Страница 44: ...Chapter 4 I O Allocation 4 1 I O Allocation 4 3...
Страница 45: ...FP I O Allocation 4 2...
Страница 51: ...FP Installation and Wiring 5 2...
Страница 77: ...FP High speed Counter and Pulse Output Functions 6 2...
Страница 133: ...FP High speed Counter and Pulse Output Functions 6 58...
Страница 135: ...FP Communication Cassette 7 2...
Страница 147: ...FP Communication Function 1 Computer Link 8 2...
Страница 169: ...FP Communication Function 2 General purpose Serial Communication 9 2...
Страница 205: ...FP Communication Function 2 General purpose Serial Communication 9 38...
Страница 207: ...FP Communication Function 3 PLC Link Function 10 2...
Страница 232: ...Chapter 11 Other Functions 11 1 Analog Potentiometer 11 3 11 2 Clock Calendar Function 11 4...
Страница 233: ...FP Other Functions 11 2...
Страница 238: ...Chapter 12 Self Diagnostic and Troubleshooting 12 1 Self Diagnostic Function 12 3 12 2 Troubleshooting 12 5...
Страница 239: ...FP Self Diagnostic and Troubleshooting 12 2...
Страница 249: ...FP Self Diagnostic and Troubleshooting 12 12...
Страница 251: ...FP Specifications 13 2...
Страница 323: ...Index FP I 4...
Страница 325: ...FP Record of changes R 2...