FP
Σ
Specifications
13 - 56
No.
Name
Boolean Operand Description
Steps
Data shift instructions
F98
Data table
shift-out and
compress
CMPR
D1, D2,
D3
Transfer “D2” to “D3”. Any parts of the data between “D1”
and “D2” that are 0 are compressed, and shifted in order
toward “D2”.
7
F99
Data table
shift-in and
compress
CMPW
S, D1, D2
Transfer “S” to “D1”. Any parts of the data between “D1”
and “D2” that are 0 are compressed, and shifted in order
toward “D2”.
7
F100 Right shift of n
bits in a 16-bit
data
SHR
D, n
Shifts the “n” bits of “D” to the right.
5
F101 Left shift of n
bits in a 16-bit
data
SHL
D, n
Shifts the “n” bits of “D” to the left.
5
F102 Right shift of n
bits in a 32-bit
data
DSHR
D, n
Shifts the “n” bits of the 32-bit data area specified by
(D+1, D) to the right.
5
F103 Left shift of n
bits in a 32-bit
data
DSHL
D, n
Shifts the “n” bits of the 32-bit data area specified by
(D+1, D) to the left.
5
F105 Right shift of
one hexadeci-
mal digit (4-bit)
BSR
D
Shifts the one digit of data of “D” to the right.
3
F106 Left shift of
one hexadeci-
mal digit (4-bit)
BSL
D
Shifts the one digit of data of “D” to the left.
3
F108 Right shift of
multiple bits (n
bits)
BITR
D1, D2, n
Shifts the “n” bits of data range by “D1” and “D2” to the
right.
7
F109 Left shift of
multiple bits (n
bits)
BITL
D1, D2, n
Shifts the “n” bits of data range by “D1” and “D2” to the
left.
7
F110 Right shift of
one word
(16-bit)
WSHR
D1, D2
Shifts the one word of the areas by “D1” and “D2” to
the right.
5
F111 Left shift of
one word
(16-bit)
WSHL
D1, D2
Shifts the one word of the areas by “D1” and “D2” to
the left.
5
F112 Right shift of
one hexadeci-
mal digit (4-bit)
WBSR
D1, D2
Shifts the one digit of the areas by “D1” and “D2” to the
right.
5
F113 Left shift of
one hexadeci-
mal digit (4-bit)
WBSL
D1, D2
Shifts the one digit of the areas by “D1” and “D2” to the
left.
5
Data buffer instructions
F115 FIFO buffer
define
FIFT
n, D
The “n” words beginning from “D” are defined in the
buffer.
5
F116 Data read from
FIFO buffer
FIFR
S, D
The oldest data beginning from “S” that was written to the
buffer is read and stored in “D”.
5
F117 Data write into
FIFO buffer
FIFW
S, D
The data of “S” is written to the buffer starting from “D”. 5
Содержание FP Series
Страница 15: ...FP Functions and Restrictions of the Unit 1 2...
Страница 25: ...FP Specifications and Functions of Control Unit 2 2...
Страница 37: ...FP Expansion 3 2...
Страница 44: ...Chapter 4 I O Allocation 4 1 I O Allocation 4 3...
Страница 45: ...FP I O Allocation 4 2...
Страница 51: ...FP Installation and Wiring 5 2...
Страница 77: ...FP High speed Counter and Pulse Output Functions 6 2...
Страница 133: ...FP High speed Counter and Pulse Output Functions 6 58...
Страница 135: ...FP Communication Cassette 7 2...
Страница 147: ...FP Communication Function 1 Computer Link 8 2...
Страница 169: ...FP Communication Function 2 General purpose Serial Communication 9 2...
Страница 205: ...FP Communication Function 2 General purpose Serial Communication 9 38...
Страница 207: ...FP Communication Function 3 PLC Link Function 10 2...
Страница 232: ...Chapter 11 Other Functions 11 1 Analog Potentiometer 11 3 11 2 Clock Calendar Function 11 4...
Страница 233: ...FP Other Functions 11 2...
Страница 238: ...Chapter 12 Self Diagnostic and Troubleshooting 12 1 Self Diagnostic Function 12 3 12 2 Troubleshooting 12 5...
Страница 239: ...FP Self Diagnostic and Troubleshooting 12 2...
Страница 249: ...FP Self Diagnostic and Troubleshooting 12 12...
Страница 251: ...FP Specifications 13 2...
Страница 323: ...Index FP I 4...
Страница 325: ...FP Record of changes R 2...