Specifications
13 - 50
Name
Boolean
Symbol
Description
Steps
32-bit data
comparison
(Start)
STD=
D=
S1, S2
Begins a logic operation by comparing two 32-bit
data in the comparative condition “(S1+1, S1) =
(S2+1, S2)”.
9
STD<>
D< > S1, S2
Begins a logic operation by comparing two 32-bit
data in the comparative condition “(S1+1, S1)
(S2+1, S2)”.
9
STD>
D>
S1, S2
Begins a logic operation by comparing two 32-bit
data in the comparative condition “(S1+1, S1) >
(S2+1, S2)”.
9
STD>=
D> = S1, S2
Begins a logic operation by comparing two 32-bit
data in the comparative condition “(S1+1, S1)
(S2+1, S2)”.
9
STD<
D<
S1, S2
Begins a logic operation by comparing two 32-bit
data in the comparative condition “(S1+1, S1) <
(S2+1, S2)”.
9
STD<=
D< = S1, S2
Begins a logic operation by comparing two 32-bit
data in the comparative condition “(S1+1, S1)
(S2+1, S2)”.
9
32-bit data
comparison
(AND)
AND=
D=
S1, S2
Connects a contact serially by comparing two
32-bit data in the comparative condition “(S1+1,
S1)=(S2+1, S2)”.
9
AND<>
D< > S1, S2
Connects a contact serially by comparing two
32-bit data in the comparative condition “(S1+1,
S1) (S2+1, S2)”.
9
AND>
D>
S1, S2
Connects a contact serially by comparing two
32-bit data in the comparative condition “(S1+1,
S1)>(S2+1, S2)”.
9
AND>=
D> = S1, S2
Connects a contact serially by comparing two
32-bit data in the comparative condition “(S1+1,
S1) (S2+1, S2)”.
9
AND<
D<
S1, S2
Connects a contact serially by comparing two
32-bit data in the comparative condition “(S1+1,
S1)<(S2+1, S2)”.
9
AND<=
D< = S1, S2
Connects a contact serially by comparing two
32-bit data in the comparative condition “(S1+1,
S1) (S2+1, S2)”.
9
32-bit data
comparison
(OR)
ORD=
D=
S1, S2
Connects a contact in parallel by comparing two
32-bit data in the comparative condition “(S1+1,
S1)=(S2+1, S2)”.
9
ORD<>
D< > S1, S2
Connects a contact in parallel by comparing two
32-bit data in the comparative condition “(S1+1,
S1) (S2+1, S2)”.
9
ORD>
D>
S1, S2
Connects a contact in parallel by comparing two
32-bit data in the comparative condition “(S1+1,
S1)>(S2+1, S2)”.
9
ORD>=
D> = S1, S2
Connects a contact in parallel by comparing two
32-bit data in the comparative condition “(S1+1,
S1) (S2+1, S2)”.
9
ORD<
D<
S1, S2
Connects a contact in parallel by comparing two
32-bit data in the comparative condition “(S1+1,
S1)<(S2+1, S2)”.
9
ORD<=
D< = S1, S2
Connects a contact in parallel by comparing two
32-bit data in the comparative condition “(S1+1,
S1) (S2+1, S2)”.
9
Содержание FP Series
Страница 15: ...FP Functions and Restrictions of the Unit 1 2...
Страница 25: ...FP Specifications and Functions of Control Unit 2 2...
Страница 37: ...FP Expansion 3 2...
Страница 44: ...Chapter 4 I O Allocation 4 1 I O Allocation 4 3...
Страница 45: ...FP I O Allocation 4 2...
Страница 51: ...FP Installation and Wiring 5 2...
Страница 77: ...FP High speed Counter and Pulse Output Functions 6 2...
Страница 133: ...FP High speed Counter and Pulse Output Functions 6 58...
Страница 135: ...FP Communication Cassette 7 2...
Страница 147: ...FP Communication Function 1 Computer Link 8 2...
Страница 169: ...FP Communication Function 2 General purpose Serial Communication 9 2...
Страница 205: ...FP Communication Function 2 General purpose Serial Communication 9 38...
Страница 207: ...FP Communication Function 3 PLC Link Function 10 2...
Страница 232: ...Chapter 11 Other Functions 11 1 Analog Potentiometer 11 3 11 2 Clock Calendar Function 11 4...
Страница 233: ...FP Other Functions 11 2...
Страница 238: ...Chapter 12 Self Diagnostic and Troubleshooting 12 1 Self Diagnostic Function 12 3 12 2 Troubleshooting 12 5...
Страница 239: ...FP Self Diagnostic and Troubleshooting 12 2...
Страница 249: ...FP Self Diagnostic and Troubleshooting 12 12...
Страница 251: ...FP Specifications 13 2...
Страница 323: ...Index FP I 4...
Страница 325: ...FP Record of changes R 2...