Specifications
13 - 16
13.4.2
Table of System Registers
Item
No.
Name
Default
value
Descriptions
Hold/
Non
5
Starting number setting for counter
1008
0 to 1024
S
In case of using
back up battery
Non-
hold 1 6
Hold type area starting number setting
for timer and counter
1008
0 to 1024
back-up battery
(option), the setting
value will be effective.
7
Hold type area starting number setting
for internal relays
90
0 to 98
value will be effective.
S
In case of not using
back-up battery
(option) please keep
8
Hold type area starting number setting
for data registers
32710
0 to 32765
(option), please keep
the default value.
Otherwise we can’t
14
Hold or non-hold setting for step
ladder process
Non-hold
Hold/Non-hold
Otherwise we can t
guarantee the function
of hold/non-hold value.
Hold/
Non-
hold 2
10
Hold type area starting number for
PLC link relays
64
0 to 64
hold 2
12
Hold type area starting number for
PLC link registers
128
0 to 128
Action
on
error
20
Disable or enable setting for dupli-
cated output
Disabled
Disabled/Enabled
error
23
Operation setting when an I/O
verification error occurs
Stop
Stop/Continuation of operation
26
Operation setting when an operation
error occurs
Stop
Stop/Continuation of operation
4
Alarm Battery Error
(Operating setting when battery error
occurs)
Disabled
Disabled: When a battery error occurs, a
self-diagnostic error is not is-
sued and the ERROR/ALARM
LED does not flash.
Enabled: When a battery error occurs, a
self-diagnostic error is issued
and the ERROR/ALARM LED
flashes.
Time
set-
ting
31
Wait time setting for multi-frame com-
munication
6500.0 ms
10 to 81900 ms
ting
34
Constant value settings for scan time Normal scan
0: Normal scan
0 to 350 ms: Scans once each specified
time interval.
0: Normal scan
0 to 350 ms: Scans once each specified
time interval.
PLC
link
40
Range of link relays used for PLC link 0
0 to 64 words
link
set-
ting
41
Range of link data registers used for
PLC link
0
0 to 128 words
ting
42
Starting number for link relay
transmission
0
0 to 63
43
Link relay transmission size
0
0 to 64 words
44
Starting number for link data register
transmission
0
0 to 127
45
Link data register transmission size
0
0 to 127 words
47
Maximum unit number setting for
MEWNET-W0 PLC link
16
1 to 16
Содержание FP Series
Страница 15: ...FP Functions and Restrictions of the Unit 1 2...
Страница 25: ...FP Specifications and Functions of Control Unit 2 2...
Страница 37: ...FP Expansion 3 2...
Страница 44: ...Chapter 4 I O Allocation 4 1 I O Allocation 4 3...
Страница 45: ...FP I O Allocation 4 2...
Страница 51: ...FP Installation and Wiring 5 2...
Страница 77: ...FP High speed Counter and Pulse Output Functions 6 2...
Страница 133: ...FP High speed Counter and Pulse Output Functions 6 58...
Страница 135: ...FP Communication Cassette 7 2...
Страница 147: ...FP Communication Function 1 Computer Link 8 2...
Страница 169: ...FP Communication Function 2 General purpose Serial Communication 9 2...
Страница 205: ...FP Communication Function 2 General purpose Serial Communication 9 38...
Страница 207: ...FP Communication Function 3 PLC Link Function 10 2...
Страница 232: ...Chapter 11 Other Functions 11 1 Analog Potentiometer 11 3 11 2 Clock Calendar Function 11 4...
Страница 233: ...FP Other Functions 11 2...
Страница 238: ...Chapter 12 Self Diagnostic and Troubleshooting 12 1 Self Diagnostic Function 12 3 12 2 Troubleshooting 12 5...
Страница 239: ...FP Self Diagnostic and Troubleshooting 12 2...
Страница 249: ...FP Self Diagnostic and Troubleshooting 12 12...
Страница 251: ...FP Specifications 13 2...
Страница 323: ...Index FP I 4...
Страница 325: ...FP Record of changes R 2...