FP
Σ
6.4 Pulse Output Function
6 - 27
Operation mode and output type
20: Type I home return
CW
21: Type I home return
CCW
22: Type I home return
Direction output off
23: Type I home return
Direction output on
24: Type I home return
CW and deviation counter reset
25: Type I home return
CCW and deviation counter reset
26: Type I home return
Direction output off and deviation counter reset
27: Type I home return
Direction output on and deviation counter reset
30: Type II home return
CW
31: Type II home return
CCW
32: Type II home return
Direction output off
33: Type II home return
Direction output on
34: Type II home return
CW and deviation counter reset
35: Type II home return
CCW and deviation counter reset
36: Type II home return
Direction output off and deviation counter reset
37: Type II home return
Direction output on and deviation counter reset
0: Fixed
Duty (on width)
0: Duty 1/2 (50%)
1: Duty 1/4 (25%)
Frequency range
0: 1.5 Hz to 9.8 kHz
1: 48 Hz to 100 kHz
2: 191 Hz to 100 kHz
H
j j j j j j j j
(
*
1):
Control code <H constant>
(
*
4): Deviation counter clear signal (ms) “K constant”
0.5 ms to 100 ms [K0 to K100]
Set value and error (0.5 ms or less)
Specify “K0” when not using or when specifying 0.5 ms.
If a value is written that exceeds the specified range of the deviation
counter clear signal, it will be revised to a value within the range.
(
*
2): Frequency (Hz) “K constant”
1.5 Hz to 9.8 KHz [K1 to K9800 (units: Hz)] (Max. error near 9.8 kHz approximately -0.9 kHz)
* Set “K1” to specify 1.5 Hz.
48 Hz to 100 KHz [K48 to K100000 (units: Hz)] (Max. error near 100 kHz approximately -3 kHz)
191 Hz to 100 KHz [K191 to K100000 (units: Hz)] (Max. error near 100 kHz approximately -0.8 kHz)
(
*
3): Acceleration/deceleration time (ms) “K constant”
With 30 steps: K30 to K32767
With 60 steps: K36 to K32767
Number of acceleration/deceleration steps
0: 30 steps
1: 60 steps (Can be specified for only Ver. 2.0 or later.)
Figure 96: FP
Σ
Control code of “F171” instruction
Содержание FP Series
Страница 15: ...FP Functions and Restrictions of the Unit 1 2...
Страница 25: ...FP Specifications and Functions of Control Unit 2 2...
Страница 37: ...FP Expansion 3 2...
Страница 44: ...Chapter 4 I O Allocation 4 1 I O Allocation 4 3...
Страница 45: ...FP I O Allocation 4 2...
Страница 51: ...FP Installation and Wiring 5 2...
Страница 77: ...FP High speed Counter and Pulse Output Functions 6 2...
Страница 133: ...FP High speed Counter and Pulse Output Functions 6 58...
Страница 135: ...FP Communication Cassette 7 2...
Страница 147: ...FP Communication Function 1 Computer Link 8 2...
Страница 169: ...FP Communication Function 2 General purpose Serial Communication 9 2...
Страница 205: ...FP Communication Function 2 General purpose Serial Communication 9 38...
Страница 207: ...FP Communication Function 3 PLC Link Function 10 2...
Страница 232: ...Chapter 11 Other Functions 11 1 Analog Potentiometer 11 3 11 2 Clock Calendar Function 11 4...
Страница 233: ...FP Other Functions 11 2...
Страница 238: ...Chapter 12 Self Diagnostic and Troubleshooting 12 1 Self Diagnostic Function 12 3 12 2 Troubleshooting 12 5...
Страница 239: ...FP Self Diagnostic and Troubleshooting 12 2...
Страница 249: ...FP Self Diagnostic and Troubleshooting 12 12...
Страница 251: ...FP Specifications 13 2...
Страница 323: ...Index FP I 4...
Страница 325: ...FP Record of changes R 2...